7. Installation
7.1. Control carefully that the environment for the installation of the high pressure cleaner considering all the
foreseen and unforeseen possibilities.
The machine is equipped with wheels, therefore it is unadvisable to
position it, without precautions, on tilted surfaces.
8. Connection to the electricity supply
8.1. The high pressure cleaner can be connected to alternating current single phase (230V) or three phase
(400V) with frequency 50Hz. For the three phase models, the high pressure cleaner is normally supplied
connected to 400 V, although can be in demand connected to 230V three phase.
8.2. For the maximum absorption of the electricity, compare the underlying chart.
8.3. Verify that the electric net, to which the machine is connected with the electric cable CA, has the
appropriate characteristics.
8.4. The high pressure cleaner is endowed with a magnetothermic switch that interrupts the power supply in
the case the absorption of the supply overcomes the value of the setting; for the location of the switch, take a
look to the electric plan attached to the machine.
8.5. The client buyer is kept to subsequently protect the line of the power supply by installing a lifesaver with
a load not exceeding 30A.
8.6. The cable is supplied without plug for the connection to the net: this must be installed by the buyer,
which will verify that:
The plug is proper for the data of the voltage and the tension above described.
The plug is conforming to the norms in force in the nation of use and that in any event it is earthed.
The connection cable and plug connection is waterproof.
8.7. If a cable with extension is used, this must have a minimum section of 4 mm
2
.
The flying thorns and
plugs are forbidden.
8.8. If the cable of connection is damaged, this must be immediately replaced with a proper cable: such
operation must be performed by specific and authorized personnel
Power
Absorption 230V Single
phase (A)
Absorption 230V Three
phase (A)
Absorption 400V Three
phase (A)
KW 2.2
13
8.5
5
KW 3
-
14
8
KW 4
-
15
8.5
KW 5.5
-
21
12
KW 7.5
-
27
16
KW 11
-
39
23
9. Connection to the water supply
9.1. The pressure of the water supply must be at least 2 bar.
9.2. The water supply must provide a flow of water of at least of the 10% of the course of the high pressure
cleaner (compare the chart with technical characteristics).
9.3. First of all, connect the water supply tap to the machine input pipefitting
IN
, using a hose with proper
diameter.
9.4. Than, connect the lance to the link of exit
OUT
.
9.5. For a long duration of the pump, avoid the use of water containing sand or other particles that
jeopardize the efficiency of the valves, the plungers and the seals.