background image

 

 

7. Installation  

7.1. Control carefully that the environment for the installation of the high pressure cleaner considering all the 
foreseen  and  unforeseen  possibilities.

 

The  machine  is  equipped  with  wheels,  therefore  it  is  unadvisable  to 

position it, without precautions, on tilted surfaces. 
 

8. Connection to the electricity supply

  

8.1. The high pressure cleaner can be connected to alternating current single phase (230V) or three phase 
(400V)  with  frequency  50Hz.  For  the  three  phase  models,  the  high  pressure  cleaner  is  normally  supplied  
connected to 400 V, although can be in demand connected to 230V three phase.  
8.2. For the maximum absorption of the electricity, compare the underlying chart.  
8.3.  Verify  that  the  electric  net,  to  which  the  machine  is  connected  with  the  electric  cable  CA,  has  the 
appropriate characteristics.  
8.4. The high pressure cleaner is endowed with a magnetothermic switch that interrupts the power  supply in 
the case the absorption of the supply overcomes the value of the setting; for the location of the switch, take a 
look to the electric plan attached to the machine.  
8.5. The client buyer is kept to subsequently protect the line of the power supply by installing a lifesaver  with 
a load not exceeding 30A.  
8.6.  The  cable  is  supplied  without  plug  for  the  connection  to  the  net:  this  must  be  installed  by  the    buyer, 
which will verify that:  
The plug is proper for the data of the voltage and the tension above described.  
The plug is conforming to the norms in force in the nation of use and that  in any event it is earthed.  
The connection cable and plug connection is waterproof.  
8.7.  If  a  cable  with  extension  is  used,  this  must  have  a  minimum  section  of  4  mm

2

.

 

The  flying  thorns  and 

plugs are forbidden. 
8.8.  If  the  cable  of  connection  is  damaged,  this  must  be  immediately  replaced  with  a    proper  cable:  such 
operation must be performed by specific and authorized personnel 
 

Power 

Absorption 230V Single 

phase (A) 

Absorption 230V Three 

phase (A) 

Absorption 400V Three 

phase (A) 

KW 2.2 

13 

8.5 

KW 3 

14 

KW 4 

15 

8.5 

KW 5.5 

21 

12 

KW 7.5 

27 

16 

KW 11 

39 

23 

 

9. Connection to the water supply  

9.1. The pressure of the water supply must be at least 2 bar. 
9.2. The water supply must provide a flow of water of at least of the 10% of the course of the high   pressure 
cleaner (compare the chart with technical characteristics).  
9.3.  First  of  all,  connect  the  water  supply  tap  to the  machine  input  pipefitting

  IN

,  using  a  hose  with    proper 

diameter. 
9.4. Than, connect the lance to the link of exit 

OUT

.  

9.5.  For  a  long  duration  of  the  pump,  avoid  the  use  of  water  containing  sand  or  other  particles    that 
jeopardize the efficiency of the valves, the plungers and the seals. 

Summary of Contents for LASER Series

Page 1: ...ctions Manual Instructions for installation and use Manufactured by MAER IDROPULITRICI SNC Via Torre 65 2 24050 Torre Pallavicina BG Tel 0039 0363 996579 Fax 0039 0363 996688 maer maeridropulitrici co...

Page 2: ...ressure cleaner 6 Transport and unpacking 7 Installation 8 Connection to the electricity supply 9 Connection to the water supply 10 Switching on 11 Switching off 12 Maintenance 13 Pump 14 Demolition 1...

Page 3: ...echnical characteristics of the machine is positioned on the machine and it is always present Please make sure when you Purchase the high pressure cleaner that the machine has this nameplate of identi...

Page 4: ...the emptying of the machine is advisable 3 7 Always protect the high pressure cleaner from the atmospheric agents from the cold and from the frost 3 8 Never direct the jet of water towards people not...

Page 5: ...21 150 2175 21 5 5 7 5 400 70 154 LASER PRO200 15 200 2900 15 4 7 5 400 70 154 LASER PRO200 21 200 2900 21 5 5 10 400 80 176 LASER EKO120 8 120 1740 8 2 1 2 5 230 40 88 LASER EKO120 11 120 1740 11 3 3...

Page 6: ...l the parts and components In the case in which the machine is damaged please call the supplier and do not use the machine We remember that the elements used in the packing of the machine could hurt t...

Page 7: ...8 6 The cable is supplied without plug for the connection to the net this must be installed by the buyer which will verify that The plug is proper for the data of the voltage and the tension above des...

Page 8: ...is advisable especially in places with temperatures below 0 C 11 4 As soon as the water flow stops switch the machine off by acting on the switch Q1 11 5 ATTENTION the operation of the pump in absence...

Page 9: ...it is to destroy well the nameplate of identification together to every other document related to the same machine 15 Problems during the operation Problem Cause Solution The inlet hoses vibrate Forei...

Page 10: ...t hose 3 Flow adjustment tap 4 Delivery hose 6 Pump 7 Motor 8 Detergent tap 9 Detergent inlet hose 10 Tank 11 Filter 12 Nozzle 13 Microswitch 14 By pass valve 15 By pass hose 16 Pressure gauge 22 Pist...

Page 11: ...sons of returning and the type of malfunction 17 4 No modifications can be made to the high pressure cleaner In case of modifications made by the customer the warranty lapses 17 5 The MAER company dis...

Page 12: ...conforms to the instructions of the 2006 42 CE machine directive and to the other following CE directives Directive 2000 14 CE Acoustic inputs Directive 2002 44 CE Vibrations Directive 2004 108 CE ex...

Reviews: