How To Install On DIN-Rails

 Mounting

 (Pictured Left)

 

Step 1)  Hook the device in an angle onto the upper 

 

 

edge of the rail.

 

Step 2)  Pull the unlocking clip.

 

Step 3)  Press the lower part of the device against  

 

 

the rail and let the clip snap into position.

Unmounting

 (Pictured Right)

Step 1)  Pull the unlocking clip.
Step 2)  Lift the lower part of the device from the 
 

rail in an angle.

Step 3)  Lift the device from the rail.

Using The MADRIX

®

 Software

You can mainly use 3 operating modes together with the MADRIX

®

 Software:

 

DMX-IN Via Art-Net 

 

DMX-IN Via Streaming ACN

 

DMX-IN Via USB

In the MADRIX

®

 Software, make sure to activate the correct drivers first:

– For USB, go to ‘Preferences’ > ‘Options...’ > ‘Devices USB’
– For sACN, go to ‘Preferences’ > ‘Options...’ > ‘Devices Network’
– For Art-Net, go to ‘Preferences’ > ‘Device Manager...’ > ‘Art-Net’

Then, configure your devices and activate input in order to receive the data:
– Go to ‘Preferences’ > ‘Device Manager...’ > ‘DMX Devices’
– Go to ‘Preferences’ > ‘Device Manager...’ > ‘DMX Input’

For more information, please read the MADRIX

®

 5 user manual.

Summary of Contents for ORION

Page 1: ...ORION Quick Start Guide T echnical Manual...

Page 2: ...ou fully understand all information This MADRIX ORION Quick Start Guide is written in English and German Diese Kurzanleitung wurde in englischer und deutscher Sprache verfasst Developed and made in Ge...

Page 3: ...actions that inoage GmbH does not have influence on no matter if the damages as well as consequential damages are direct or indirect whether they are special damages or others nor if the damage is cau...

Page 4: ...ny other liquids Turn off the power if you are not using the device for a long time Avoid unwanted voltage on the cables at all times Do not remove any parts from the unit or connect to an ungrounded...

Page 5: ...he same time Technical Specifications Supply of power See pages 6 9 Power supply As provided external Power consumption Input signals Ports Input pins Ethernet USB port Case Dimensions Weight Temperat...

Page 6: ...e the MADRIX Software in order to access all features of MADRIX ORION including the USB connection which requires MADRIX 5 Support for Art Net Streaming ACN is already available with previous versions...

Page 7: ...port incl 2 status LEDs 4 USB port 5 Status LED for Power 6 Status LED for USB 7 Status LED for Port 1 8 Status LED for Port 2 9 Port 1 10 Reset button 11 DIN rail unlocking clip 12 Port 2 2x Mounting...

Page 8: ...vely use the provided external power supply Make sure to switch to 5 V yellow arrow on the power adapter itself by using a suitable tool up to 12 V or when using your own power supply up to 24 V You c...

Page 9: ...required for GROUND Connection required for DATA Connection required for V Example A Description Power is supplied only once to ORION and also used for the input equipment Each Port is protected with...

Page 10: ...lus a 1k 10k resistor Example C Description Power is supplied to ORION and supplied separately to the input equipment The sensor is connected to Port 1 via GROUND and DATA at Pin 1 but not V Example D...

Page 11: ...art the MADRIX Software Step 3 In the MADRIX Software go to Tools MADRIX Device Configuration A new window will open Click on the search button loupe icon and the software will search for connected de...

Page 12: ...een as described on page 12 Start the MADRIX Software and enable USB drivers Go to Preferences Options tab Devices USB Activate MADRIX ORION and click OK The driver is activated by default Step 2b For...

Page 13: ...f No data is sent No data is sent Blinking green Receiving data changes The input port works Receiving data changes The input port works STATUS STATUS LEDS ETHERNET PORTS Green off 10 MBit s connected...

Page 14: ...rail Using The MADRIX Software You can mainly use 3 operating modes together with the MADRIX Software DMX IN Via Art Net DMX IN Via Streaming ACN DMX IN Via USB In the MADRIX Software make sure to ac...

Page 15: ...formity The device complies with the requirements set forth in the council Directive of the law of the Member States relating to electromagnetic compatibility 2014 30 EU the Low Voltage Directive 2014...

Page 16: ...g ACN is recommended for large projects by connecting multiple devices to a switch 1 GBit s via suitable components to create a network or use the built in daisy chain support see page 8 Where can I f...

Page 17: ...onen verstanden haben Diese Kurzanleitung wurde in englischer und deutscher Sprache verfasst This MADRIX ORION Quick Start Guide is written in English and German Entwickelt und hergestellt in Deutschl...

Page 18: ...keinen Einfluss hat ganz gleich ob es sich um direkte oder indirekte Sch den Folgesch den oder spezielle Sch den handelt und ob diese vom Besitzer oder einer dritten Person verursacht wurden Eingetra...

Page 19: ...iten Trennen Sie das Ger t bei l ngerer Nichtbenutzung von der Spannungsversorgung Entfernen Sie keine Teile vom Ger t oder andere Bauteile und verbinden Sie es niemals mit einem ungeerdeten Stromkrei...

Page 20: ...rsorgung Siehe Seiten 6 9 Netzteil Mitgeliefert extern Stromaufnahme Eingangssignale Ports Eingangspins Netzwerk USB Anschluss Geh use Abma e Gewicht Temperaturbereich Relative Luftfeuchte 5 V 24 V Gl...

Page 21: ...SB Verbindung welche MADRIX 5 ben tigt wird die MADRIX Software empfohlen Art Net und Streaming ACN werden bereits von vorherigen Versionen unterst tzt Min Systemanforderungen f r MADRIX und unterst t...

Page 22: ...inks inkl 2 Status LEDs 4 USB Anschluss 5 Status LED f r Strom 6 Status LED f r USB 7 Status LED f r Anschluss 1 8 Status LED f r Anschluss 2 9 Anschluss 1 Port 1 10 Reset Taste 11 Hutschienen Entrieg...

Page 23: ...mitgelieferte Netzteil verwendet werden Dabei muss 5 V gelber Pfeil auf dem Netzteil selber mit einem passenden Werkzeug eingestellt werden bis zu 12 V oder bei Nutzung eines eigenen Netzteils bis zu...

Page 24: ...bindung erforderlich f r V Die Eingabeger te und ORION k nnen auf verschiedene Arten verbunden werden Auf den folgenden Seiten sind verschiedene Beispiele dargestellt Diese sind unabh ngig von der Aus...

Page 25: ...it 1k 10k angeschlossen Beispiel C Beschreibung Die Spannungsversorgung wird f r ORION und das Eingabeger t separat bereit gestellt Der Sensor ist an Port 1 ber MASSE und DATEN an Pin 1 angeschlossen...

Page 26: ...MADRIX ORION mit Ihrem Computer ber USB Schritt 2 Starten Sie die MADRIX Software Schritt 3 ffnen Sie in der MADRIX Software das Men Werkzeuge MADRIX Ger tekonfiguration Bet tigen Sie das Lupen Symbo...

Page 27: ...MADRIX Software die Treiber unter Systemeinstellungen Optionen Reiter USB Ger te MADRIX ORION aktivieren Mit OK best tigen Der Treiber ist standardm ig aktiviert Schritt 2b F r die Netzwerkverbindung...

Page 28: ...at keinen Strom Permanent gr n Spannungsversorgung liegt an Das Ger t hat Strom Gr n blinkend Bootloader aktiviert Zur cksetzen Firmware einspielen STATUS STATUS LED USB Ausgeschaltet USB nicht angesc...

Page 29: ...Art Net Danach k nnen Ger te und Datenempfang konfiguriert und aktiviert werden Systemeinstellungen Ger teverwaltung DMX Ger te Systemeinstellungen Ger teverwaltung DMX Eingang Montage auf Hutschienen...

Page 30: ...dhabung oder technische Probleme auftauchen konsultieren Sie bitte die weiteren Benutzerhandb cher kontaktieren Sie Ihren H ndler oder besuchen Sie die Internetseite www madrix com Anfragen k nnen auc...

Page 31: ...treaming ACN wird f r gro e Projekte mit mehreren Ger ten empfohlen Diese ber geeignete Komponenten mit einem Switch 1 GBit s als Netzwerk verbinden oder die eingebaute Netzwerkreihenschaltung nutzen...

Page 32: ...www madrix com...

Reviews: