background image

E4

TECHNICAL DETAILS - OIL PUMP ASSEMBLY

SAFETY INSTRUCTIONS

When the pump is connected to the compressed air supply:

1. The compressed air must be filtered to avoid dust and moisture into pump.

2. The max compressed air pressure must not exceed 0.8Mpa/120psi.

3. To deliver oil, press the knob on the delivery pistol; delivery stops when the knob is released 

but the whole system remains under pressure.

4. Position the pistol so that the circuit can’t open accidentally. Otherwise oil could leak onto 

the ground.

5. Never point the pistol at people or object.

6. Press the pistol knob.

7. Always cut off the air supply after use so that oil can’t leak out in case one of the pump’s 

components should break.

8. Use only original spare parts in case the pump has to be repaired or its components have to 

be replaced.

9. Empty all the oil from the pump in case it has to be disposed of.

10. When not in use, turn off compressed air to stop pump.

11. Do not use the pump near open flames. Do not smoke during this operation.

12. Wear oil-proof gloves.

13. Do not throw the oil away. Used oil has to be disposed of according to national 

environmental regulations.

14. The pumps can be used only to deliver lubricants, used oil or antifreeze liquids. Do not use 

the pump for any other substance.

THE MANUAL OF OIL PUMP

Read the following precautions and instructions before you begin assembly or using. 

Failure to comply with these instructions could result in personal injury or property damage. 

Keep these instructions in a convenient location for future reference.

IMPORTANT NOTE

The guarantee will be void if the pump has been altered in any way.

PROFILE

Oil pumps can be used to transfer lubrication oil, waste oil and antifreeze liquids.

This manual is applicable to the following pump only, please confirm your pump is included.

Item No.
Drum application  

 

Pressure ratio 
Air inlet pressure 
Max. fluid pressure    
Air motor effective diameter 

 

Air consumption (per minute)

Max.free flow rate (per minute)
Suction tube diameter 
Suction tube length 
Air inlet connection
Oil outlet connection

1701036

180-220L / 48-58gallon
3:1
5-8bar / 70-115psi 
24bar / 350psi
63mm / 2.5"
@ 8bar / 140L 
@ 115psi / 5.0CFM 
28L / 7.4gallon
42mm / 1-5/8" 
940mm / 37" 
1/4" NPT Female 
3/4" M

1701056

180-220L / 48-58gallon
5:1
5-8bar / 70-115psi 
40bar / 580psi
63mm / 2.5"
@ 8bar / 140L 
@ 115psi / 5.0CFM 
25L / 6.6gallon
42mm / 1-5/8" 
940mm / 37" 
1/4" NPT Female 
3/4" M

Summary of Contents for OKT583-1-001

Page 1: ...re to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read when required Keep t...

Page 2: ...ment and do not use this equipment for a purpose for which it was not intended 4 Check for damaged parts Before using this product carefully check that it will operate properly and perform its intende...

Page 3: ...outlet of oil pump 2 2 Lock the female thread of oil hose 4 on the male thread of adapter 3 1 Lock the male thread of oil delivery hose 4 on the inlet of oil control valve assembly 5 Step 3 Step 4 2...

Page 4: ...r of defective material within the warranty period when returned freight prepaid to the distributor or their designated service depot 3 The warranty does not cover damage caused by accident misuse or...

Page 5: ...No 1 2 3 4 5 6 7 8 9 Description Accessories Drum Holder Support Handle Pump Support Hexagon Screw Set Stopper Accessories Support Acom Nut Washer Q ty 1 1 1 2 3 1 1 2 2 Part No 10 11 12 13 14 15 16 1...

Page 6: ...sposed of according to national environmental regulations 14 The pumps can be used only to deliver lubricants used oil or antifreeze liquids Do not use the pump for any other substance THE MANUAL OF O...

Page 7: ...hed with a lubricator please pay close attention to the lubricator s oil level and refill with SAE 20 SAE 30 or antifreeze oil for extreme conditions when necessary NOTE The user should perform only r...

Page 8: ...ction is 1 4 quick plug or 1 4 NPT female in all versions Compressed air connection to be supplied by the customer should be done using suitable tube 5 A pressure regulator to keep the pump s working...

Page 9: ...EXPLODED AND PARTS LIST 3 1 OIL PUMP E7...

Page 10: ...ide cover Outlet Part No 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 Description Piston connect cover Suction tube Piston shaft Connector O ring Spring circlip Bal...

Page 11: ...EXPLODED AND PARTS LIST 5 1 OIL PUMP E9...

Page 12: ...affle Small piston Piston cover Cut cover Part No 27 28 29 30 31 32 101 102 103 104 105 106 107 108 109 201 202 203 204 205 206 207 208 209 210 Description Side cover Outlet Suction tube Spring circli...

Page 13: ...ipment manuals Read the fluid and solvent manufacturer s warnings 8 Route hose away from traffic areas sharp edges moving parts and hot surfaces 9 Do not lift pressurized equipment 10 Comply with all...

Page 14: ...inlet 2 Air shut off valve 3 Oil pump 4 Fluid shut off valve 5 Meter 6 Hose reel 7 Control valve NEW INSTALLATION 1 Relieve the pressure To reduce the risk of serious injury whenever you are instructe...

Page 15: ...en all dispense position shut off valves and start the pump to pressurize the system See the Operation section for proper operation 7 For metered dispense valves to ensure dispensing accuracy purge al...

Page 16: ...ess Menu key again for 3 seconds then exit the calibration mode The calibration settled Show Current Correction Factor 1 Press Menu key and Reset key together The display will show the correction fact...

Page 17: ...ng valve extension or nozzle is clogged or that pressure has not been fully relieved after following the steps above very slowly loosen a fitting on the fluid line to relieve pressure gradually then l...

Page 18: ...distributor for repair or replacement Replace the o ring If the problem remains contact your distributor for repair or replacement Inspect the nozzle for damage or obstructions and replace if damaged...

Page 19: ...lter Adapter O ring Meter Holder Meter Cover Rubber Protector Q ty 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 Part No 3 5 3 6 3 7 3 8 3 9 3 10 3 11 3 12 3 13 3 14 3 15 3 16 3 17 3 18 3 19 3 20 3 21 4 Descrip...

Page 20: ...Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use 2 09 05 30 1078 Size 145x210mm REV 03 11 22 157...