995565 – Revision A
Page 18 of 38
Step 4 - Remove the cable from any clips that are routing it along the Mast.
Refitting / Replacement
Step 5 - Refitting is a reversal of the removal process noting the following points:
A)
When fitting the Cable into the Actuator port, ensure the locator aligns with the
locator inside the actuator port.
9.2.3 – Cable – Leg Actuator
Removal
Step 1 – Remove the Jack End of the Cable which ports the Control Box by pulling
downward. (This is the port on the right hand side of the Control Box as shown in the image)
Step 2 – Release the cable from the Actuator by removing the locking device. It is
recommended a flat head screwdriver is used. Push the latch outward and push the part
downward to remove.
Step 3 – Remove the Cable by pulling it out the port, action may be easier using a flat head
screwdriver.