995565 – Revision A
Page 25 of 38
Step 6 – The Upper Assembly can now be removed.
Refitting / Replacement
Step 7 - Refitting is a reversal of the removal process noting the following point:
A)
Ensure the threaded boss is placed within the Upper Assembly when fitting.
B)
Ensure Loctite 243 is applied to both bolts when fixing the Upper Assembly.
C)
When fitting the Upper Assembly, ensure it is orientated correctly. The Assembly
should curve upward not downward. See image for reference.
D)
Press the End Cap in manually using your hand to avoid unwanted damage.