The “Wheel-angle calibration” menu has a step-by-step method to calibrate the
wheel-angle sensor. Follow the steps in order to perform a wheel-angle sensor
calibration:
Option
Comment/Function
1
Go straight ahead
Move forward and ensure that the
wheels are in a straight forward position,
then press “Done”.
2
Stop the tractor
Stop the tractor, then press “Done”.
3
Turn the wheel to the right end
position
Turn the wheel to the right end position,
then press “Done”.
4
Turn the wheel to the left end
position
Turn the wheel to the left end position,
then press “Done”.
5
Wheel movement calibration
Leave the tractor at a standing position,
do not stop the engine or turn the wheel
To prevent accidental death or injury from being run over by the vehicle
make sure that the vehicle is clear of any obstacles or humans while
calibrating the MachineryGuide AutoSteer system.
12