PRE-DELIVERY CHECKS
Form # 169080
Issue – April 2007
35
d. Check timing flange bolts (C) are tight.
e. Manually turn rolls in opposite direction to
release gauge.
f. Replace gauge in header with bolt (A) and nut.
D. LUBRICATE THE HEADER
The header has been lubricated at the factory.
However, it is recommended to lubricate the
header prior to delivery to offset the effects of
weather during outside storage and transport,
and to familiarize the dealer with the machine.
Refer to the illustrations on the following pages
for lubrication points.
•
Wipe grease fitting with a clean cloth
before greasing, to avoid injecting dirt and
grit.
•
Inject grease through fitting with grease
gun until grease overflows fitting, except
where noted.
•
Leave excess grease on fitting to keep out
dirt.
•
Replace any loose or broken fittings
immediately.
•
If fitting will not take grease, remove and
clean thoroughly. Also clean lubricant
passageway. Replace fitting if necessary.
(continued next page)
C
A
B