MAINTENANCE/SERVICE
Form 169469/169470/169471
165
Revision C
7.10.1.3 Charging
CAUTION
•
Ventilate the area where batteries are
being charged.
•
Do not charge a frozen battery. Warm to
60
°
F (16
°
C) before charging.
•
Do not connect or disconnect live
circuits. To prevent sparks, turn off
charger and connect positive cable first.
If charging battery in windrower,
disconnect positive battery cable before
connecting charger cable, then connect
ground cable last, away from battery.
•
Stop or cut back charging rate if battery
feels hot, or is venting electrolyte.
Battery temperature must not exceed
125
°
F (52
°
C).
•
Follow all instructions and precautions
furnished by the battery charger
manufacturer. Charge at recommended
rates and times.
7.10.1.4 Boosting
A twelve volt battery can be connected in
parallel (+ to +) with the windrower battery. Use
heavy duty battery cables.
CAUTION
•
Gas given off by batteries is explosive.
Keep sparks and flames away from
batteries.
•
Make last connection and first
disconnection at a point furthest away
from the batteries.
•
Wear protective eye-wear when using a
booster battery.
•
Be sure everyone is clear of machine
when starting engine. Start engine from
operator's station only.
a. Move platform on right cab-forward side of
machine to open position to allow access to the
battery.
b. Remove red rubber cover (A) from windrower
battery positive terminal.
(continued next page)
A
Summary of Contents for M205 2010
Page 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Revision C Part 169469 25...
Page 51: ...OPERATOR S STATION Form 169469 169470 169471 49 Revision C continued next page...
Page 95: ...HEADER OPERATION D SERIES Form 169469 169470 169471 93 Revision C continued next page...
Page 181: ...MAINTENANCE SERVICE Form 169469 169470 169471 179 Revision C 7 10 13 3 Fuse Box Decal...