This alarm is visualised on display by code 81
Solution: check the following :
a)
check the power supply of the gsm modem installed in the coffee machine.
b)
check that the serial cable is properly connected in the gsm modem and in the master board (CN 16).
20)
N°82 PIN of the modem gsm alarm ( only for machine with GSM Modem kit )
PIN ERROR 82
This alarm is visualised on display by code 82
Solution: check that the PIN number programmed in the parameters “GSM : SIM CARD PIN “ is the same as the Sim card
inserted in the gsm Modem .
21)
N° 90 Water softener alarm.
Change H2o filter 90
This alarm is visualised on display by code 90
Cause: the flowmeter has reached the maximum value of XXXXX litres of previously programmed water, which may be
dispensed.
Result: none.
Solution: renew the softener salts. To cancel the alarm, see the Info -Reset paragraph for further information.
Note: this alarm does not block dispensing. The softener alarm can be excluded by setting the litre value to zero (see
Service – Maintenance set-up paragraph).
22)
N° 91 Group maintenance alarm.
Group maintena. 91
This alarm is visualised on display by code 91
Cause: the group has reached the number of programmed cycles (see Service chapter).
Result: none.
Solution: check the group and cancel the alarm following the procedure of the chapter info reset.
23)
N° 92 Machine maintenance alarm.
Maintenance 92
This alarm is visualised on display by code 92
Cause: the machine has reached the number of programmed cycles or the inspection date (see Service chapter).
Result: none.
Solution: check or/and replace the wear parts and cancel the alarm following the procedure of the chapter Info reset.
24)
N° 93-Tools maintenance alarm.
Grinder mainte. 93
This alarm is visualised on display by code 93
Cause: the tools have reached the set up working time (see Service chapter )
Result: none.
Solution: replace the tools and cancel the alarm following the procedure explained in the info reset chapter.
Summary of Contents for ILC-200
Page 18: ...Pag 18 27 03 2014 INFO RESET A1 READ DOSES DATA Doses counter A B esc...
Page 19: ...Pag 19 27 03 2014 A2 READ DOSES DATA Reset doses counter A B...
Page 20: ...Pag 20 27 03 2014 B INFO RESET SYSTEM DATA...
Page 29: ...Pag 29 27 03 2014...
Page 33: ...Pag 33 27 03 2014...
Page 36: ...lb 05061 02 EN Pag 36 27 03 2014...
Page 39: ...Pag 39 27 03 2014 DISPLAY REGULATION...
Page 42: ...Pag 42 27 03 2014...
Page 43: ...Pag 43 27 03 2014...
Page 44: ...Pag 44 27 03 2014...
Page 46: ...Pag 46 27 03 2014...
Page 50: ...lb 05061 02 EN Pag 50 27 03 2014 1 1 3 3 5 5 7 7 2 2 4 6 4 6 esc esc V esc...
Page 59: ...Pag 59 27 03 2014...