11) N° 38 Steam boiler temperature alarm.
Steam temperat. 38
This alarm is visualised on display by code 38
First case: the temperature inside the steam boiler has reached the limit value of 129°C (264.2°F) or more.
Result: boiler heating is interrupted and all dose buttons are disabled.
Solution: turn OFF the machine. Replace the TRIAC of the heating element steam boiler. Turn the machine ON.
Second case: the temperature probe is defective. The probe sends the following signal to the pcb: 0 Ohm.
Result: boiler heating is interrupted and all dose buttons are disabled.
Solution: turn OFF the machine. Replace the temperature probe. Turn the machine ON.
Third case: the temperature probe is defective. The probe sends the following signal to the pcb: 154 Ohm (short circuit).
Result: boiler heating is interrupted and all dose buttons are disabled.
Solution: turn OFF the machine. Replace the temperature probe. Turn the machine ON.
12) N° 40 Flowmeter alarm.
Flowmeter error 40
This alarm is visualised on display by code 40.
Cause: the flowmeter is not sending signals to the control unit within a time-out of 5 seconds.
Result: delivery continues up to a time-out of 120 seconds or until the selected key is pressed.
Check the following:
1)
No water from mains (coffee is not dispensed)
2)
clogged group piston filters (coffee is not dispensed)
3)
faulty group solenoid valve (coffee is not dispensed)
4)
clogged inlet filters (coffee is not dispensed)
5)
blocked flowmeter (coffee is not dispensed)
6)
or faulty flowmeter (coffee dispensed continuously)
7)
faulty electrical connection (coffee dispensed continuously).
Note: If the coffee is dispensed continuously, use the machine as if it were manual: press the required key to start up the
dose, then press the same key to stop the dose being dispensed, after checking the amount in the cup.
If dispensing continues until the above mentioned time-out of 120 seconds, the dispensing will be stopped and display
shows:
Infusion T.O. 41
This alarm is visualised on display by code 41.
The message signals that a time-out problem of the flowmeter occurred.
At the next dose the message will be cancelled if dispensing is carried out correctly.
13) N° 60 Corrupted data alarm.
Corrupted data alarm 60
This alarm is visualised on display by code 60
First case: This alarm is visualised during machine functioning
Cause: incorrect operating data in machine memory.
Result: machine shutdown.
Solution: carry out the following controls.
1)
Verify programming data relevant to the operation that is being carried out. They might be varied and therefore the
machine does not recognise the new data.
2)
Carry out “PARAMETERS PRESET” procedure (see chapter system programming configuration data preset).
Second case: software programming values or data incorrect, data inserted by means of P.C. programming incorrect.
Result: machine shutdown.
Solution:
1)
Carry out “PRESET CONFIGURATION DATA” procedure
2)
Insert new software by means of P.C.
Summary of Contents for ILC-200
Page 18: ...Pag 18 27 03 2014 INFO RESET A1 READ DOSES DATA Doses counter A B esc...
Page 19: ...Pag 19 27 03 2014 A2 READ DOSES DATA Reset doses counter A B...
Page 20: ...Pag 20 27 03 2014 B INFO RESET SYSTEM DATA...
Page 29: ...Pag 29 27 03 2014...
Page 33: ...Pag 33 27 03 2014...
Page 36: ...lb 05061 02 EN Pag 36 27 03 2014...
Page 39: ...Pag 39 27 03 2014 DISPLAY REGULATION...
Page 42: ...Pag 42 27 03 2014...
Page 43: ...Pag 43 27 03 2014...
Page 44: ...Pag 44 27 03 2014...
Page 46: ...Pag 46 27 03 2014...
Page 50: ...lb 05061 02 EN Pag 50 27 03 2014 1 1 3 3 5 5 7 7 2 2 4 6 4 6 esc esc V esc...
Page 59: ...Pag 59 27 03 2014...