background image

8

defects or deterioration that might compromise the original safety of the equipment. The standard
high pressure cleaner is not equipped to work in an environment in which particular inflammable or
explosive conditions are present; flameproof equipment is only supplied upon specific request.
It is forbidden to install the machine in conditions where there are inflammable products (caution is
required in environments with air-suspended particles: plastic materials, resins, acids, inks etc.)
Adhere to the regulations laid down by the fire brigade.
The diesel oil tank must only be filled with the machine disconnected from the electricity supply; it
is strictly forbidden to smoke or approach with a naked flame during refuelling.
The hot water high pressure cleaner have been tested to give clean, economical fuel burning which
does not harm the environment and is free of unburnt residues.
Nevertheless, exhaust gases (in particular CO) are harmful and lethal if inhaled to an excessive
extent.
When the machine is being operated in an enclosed area (garages, sheds etc.) an exhaust gas
extractor should be available as well as suitable ventilation for the recycling of the carburant air
supply and for reinstatement of the air supply.
The vent terminal must absolutely never be obstructed.
Do not lean objects or the lance itself in proximity to the exhaust outlet.
The exhaust outlet should be considered as dangerous both for exhaust gases and for its high
temperature. Inform operators appropriately in order to avoid burns. Never leave the machine in
unattended operation, particularly in the presence of children.
The use of extensions and plug extensions is forbidden.
The work environment is necessarily exposed to water and humidity that preclude the normal
conditions of insulation of the equipment.
Check the integrity and insulation of the electric cable as well as the operator’s equipment.
Do not touch the plug with wet hands or feet!
Avoid accidentally switching on the machine; position the switch at OFF before inserting and
withdrawing the plug form the socket. Do not pull the machine by electrical supply cable; do not
pull the cable in order to withdraw the plug.
Do not use the equipment if damage or deterioration to it has been noticed; disconnect the equipment
form the electricity supply and turn to an authorised servicing centre.
Chemical detergents must be used with care in order not to damage the machine components and
the environment (degradability of over 90%). Updated  at D.LGs 25/02
Always check the degradability and harmfulness of products used.
Do not use paints, acids, solvents, oily or very thick liquids, etc.
Protect the machine from frost and atmospheric weather conditions in general.
Starting the machine off when cold may cause serious damage to the pump and circuit.
If the machine is not used for a long time and is kept at a temperature below 0°C (zero degrees
Celsius) this may cause damage or breakages to the pump and pipe work; it is advisable, therefore
to empty the machine completely.
Do not direct the water jet at persons or animals; nor at the machine itself nor, in any event, at any
object under tension of an electrical current.
Never direct the jet at yourself or at other people in order to clean clothing or footwear.

Summary of Contents for DROP Series

Page 1: ...USER MANUAL INSTRUCTIONS FOR INSTALLATION AND USE www macinternational co uk MAC DROP ...

Page 2: ...U D EAU FUNZIONAMENTO ACCENSIONE MACHINE OPERATION SWITCHING ON ALLUMAGE ARRESTO SWITCHING OFF ARRET MANUTENZIONE MAINTENANCE MAINTANENCE POMPA THE PUMP POMPE CALDAIA THE BOILER CHAUDIERE ELETTRODI THE ELECTRODES ELECTRODES FILTRO GASOLIO THE DIESEL OIL FILTER FILTRE A GASOIL FILTRO ACQUA THE WATER FILTER FILTRE A EAU DEMOLIZIONE DEMOLITION DEMOLITION DIAGNOSI TROUBLESHOOTING GUIDE DIAGNOSTIC 4 4 ...

Page 3: ...directions contained herein the manufacturer shall not be held liable for damage caused to persons and or property or sustained by the machine itself should the instructions set out hereafter not be adhered to Thismanualisanintegralpartofthemachine itmustbepreservedwithcarefortheentireduration of the life of the machine until it is to be scrapped The manufacturer reserves the right to modify his p...

Page 4: ...t and the possible chemical action of detergent additive or disinfectant liquids etc by means of a high pressure jet of hot water By means of appropriate accessories it is possible to clean descale sandblast disinfect etc The purposes for which the high pressure cleaner is intended to be used must be scrupulously respected and every other use is to be considered as improper IDENTIFICATION PLATE Th...

Page 5: ...nale di manutenzione deve avere caratteristiche specifiche tecnico manutentore in grado di interpretare correttamente schemi ed istruzioni Lamacchinavautilizzatadaunsolooperatore adulto nonlasciaremailamacchinaincustoditain particolare in presenza di bambini REQUISITE CHARACTERISTICS OF OPERATORS Theoperatorofthemachinemusthavespecificprofessionaltrainingordueexperienceofmachines ofthistype Inorde...

Page 6: ... funzionamento applicate direttamente sul prodotto nè tantomeno le norme di sicurezza vigenti nel paese di installazionee le regole dettate dal comune buonsenso L installatore o il manutentore ha l obbligo di segnalare eventuali difetti o deterioramenti che possano compromettere l originale sicurezza dell impianto L idropulitrice di serie non è equipaggiata per lavorare in ambienti che presentano ...

Page 7: ... pompa e al circuito La sosta prolungata fermo macchina a temperatura inferiore a 0 C zero gradi centigradi può provocare danneggiamenti o rotture di pompa e tubazioni è consigliabile pertanto il completo svuotamento Non dirigere il getto dell acqua su persone o animali né tantomeno sulla macchina o comunque su qualsiasi oggetto in tensione alimentato da energia elettrica Non dirigere mai il getto...

Page 8: ...he machine in unattended operation particularly in the presence of children The use of extensions and plug extensions is forbidden The work environment is necessarily exposed to water and humidity that preclude the normal conditions of insulation of the equipment Check the integrity and insulation of the electric cable as well as the operator s equipment Do not touch the plug with wet hands or fee...

Page 9: ...Pompiersetlescollectivités locales du lieu d installation Le réservoir de gasoil doit être rempli lorsque la machine est débranché Il est sévèrement interdit de fumer ou d utiliser des flammes libres durant le remplissage du réservoir Nos hydronettoyeurs à eau chaude équipés d un brûleur et d une chaudière ont été testés en vue d une combustion èconomique et propre qui respecte l environnement et ...

Page 10: ... des températures inferieures a 0 C zéro degré centigrade peut endommager la pompe et les conduites ou en provoquer la rupture Il est dès lors conseillé d en faire la vidange totale Evitez d orienter le jet d eau sur des personnes ou des animaux Evitez également la machine ou tout objet branché sur le réseau électrique N orientez jamais le jet sur votre propre personne ou autrui pour le nettoyage ...

Page 11: ...in Potenza Installata Istalled Power Puissance Installée Kw Hp Voltaggio 50Hz Voltage 50Hz Voltage 50Hz Volt Temp Acqua Water Temp Temp Eau C Peso Weight Poid Kg 2800 RPM STRUMENTAZIONE INSTRUMENTATION INSTRUMENTS IF Interruttore generale ON OFF switch Interrupteur TR Termostato Thermostat Thermostat MA Manometro Pressure gauge Manométre TRASPORTO E DISIMBALLO Per il sollevamento e il trasporto se...

Page 12: ...e operators etc who are provided with appropriate lifting equipment designed to bear the weight of the various components Transportation of the machine in particular by road must be carried out using appropriate means and methods in order to protect the components in particular electronic components from violent bumps humidity vibration etc themachinesaresuppliedwithwheelsandthereforeitisnecessary...

Page 13: ...tilisés pour l elimination des emballages ciseux marteaux tenailles couteaux etc Quelques composants peuvent être fornis non installés c est pourtant indispensable les installer en respectant les instructions de ce manuel INSTALLAZIONE E opportuno valutare attentamente l ambiente di installazione considerando tutte le preclusioni previste nel presente manuale ed anche quelle non prevedibili La mac...

Page 14: ...e minima di 2 5mmq se il cavo è lungo fino a 20m oppure di 4mmq se il cavo è pù lungo di 20m è vietato l uso di spine volanti utilizzare eventuali avvolgitori N B QualorailcavodialimentazioneCAvengadanneggiatodeveessereimmediatamentesostituito con un cavo adeguato tale operazione va effettuata da personale competente e autorizzato CONNECTION TO THE ELECTRICITY SUPPLY Thehighpressurecleanercanbesup...

Page 15: ... doit convenir en fonction des données électriques et de voltage ci dessus 2 La fiche doit être conforme aux normes en vigueur dans le pays où la machine est utilisée et quoi qu il en soit être équipée d une mise à la terre 3 La connexion câble fiche doit être étanche 4 Les rallonges lorsqu elles sont utilisées doivent avoir les caractéristiques ci après section minimum de 2 5 mmq pour un câble de...

Page 16: ...ake in air and will be subject to overheating and vibration with consequent serious damage to the pump itself and to the machine The water supply input must provide a flow of water greater by at least 10 of the capacity of the machine see the table CHARACTHERISTICS Connectwatersupplytaptothemachineinputpipefitting IN using a tube which has _ diameter pipefittings and the lance to the output pipefi...

Page 17: ...inférieur à celui du raccord de connexion machine Qui plus est il doit être monté pour éviter la formation de bulles d air L eau d alimentation peut atteindre tout au plus 75 C et une pression maximum de 8 bar Les joints et d autres organes de la pompe subissent des dommages irréparables lorsque la machine tourne à sec même pendant quelques instants Contrôlez le robinet de branchement sur le résea...

Page 18: ...r éviter les jets accidentels Branchez la sécurité lorsque la lance n est pas utilisée La machine est ainsi prête à l emploi avec de l eau froide Réglez èventuellement le dèbit pression à l aide du robinet RP pour régler le débit Si vous souhaitez utiliser des détergents mettez le dans le récipient Pour le fonctionnement à chaud applyer sur l interrupteur I pos ON régler la température de l eau pa...

Page 19: ...ent la machine positionnez l interrupteur IF su la pos 0 Si la machine à été alimentée avec de l eau chaude il vaut mieux avant d éteindre l interrupteur IF baisser la température en faisant tourner le thermostat TR vers la droite Positionnez le sur zéro etfaitestournerlamachinependant2minutesavecdel eaufroidepourqueleserpentinrefroidisse Encasdelonguesinterruptionsdufonctionnementdelamachine ilva...

Page 20: ...olio smontare la testata e sostituire le guarnizioni della testata Per questa operazione è tuttavia consigliabile rivolgersi ad un centro di assistenza specializzato Riavviando la pompa dopo la manutenzione o la riparazione è necessario accertarsi che questa sia rifornita d olio L olio va sostituito dopo le prime 50 ore di funzionamento e successivamente ogni 200 ore Si usi esclusivamente olio ESS...

Page 21: ... seguente 1 Smontare il gruppo caldaia bruciatore dalla macchina e separare la caldaia dal bruciatore 2 Togliere il coperchio della caldaia 3 Rimuovere la fasciatura della caldaia liberando la serpentina 4 Usare una spazzola rigida per rimuovere la fuliggine dalla serpentina ed un aspiratore per rimuovere la polvere 4 Rimontare fasciatura coperchio e bruciatore e installare il gruppo sulla macchin...

Page 22: ...diesel oil the diesel oil circuit is supplied with a filter that must be periodically disassembled and cleaned with a jet of compressed air Replace the filter when it becomes impossible to clean it adequately FILTRE A GASOIL Pour éviter le grippage de la pompe ou une rupture à cause des impurités présentes dans le gasoil le circuit à gasoil doit être équipé d un filtre Ce dernier doit être démonté...

Page 23: ... rules in terms of production possession collection and waste disposal D Lgs 22 97 of the Italian Law Spent oils must be disposed of to nationalWaste Treatment Companies Packing if any must be disposed of according to the regulations underTit II Decree n 22 97 of the Italian Law Note The MAER company disclaims all responsibility for damages to persons and or things deriving from re use of single p...

Page 24: ...l flusso d aria per mezzo della serranda di regolazione Adjust airflow by means of airlock Réglez le débit d air au moyen du d une rideau de réglage 2 Ruotare in senso anti orario la vite di regolazione della pressione gasolio Turn diesel oil pressure regulation screw in clockwise direction Faitez tourner la vis de réglage de la pression du gasoil à gauche 3 Pulire la serpentina della caldaia Clea...

Page 25: ...pentino e lavarlo all in terno con liquido disincrostante Clean coil and wash internally with descaling fluid Nettoyez le serpentin et lavez le à l intétieur avec du liquide qui élimine les incristations 2 Rimuovere e pulire ugello Remove and clean nozzle Déposez et nettoyez le gicleur 3 Rimuovere e pulire accuratamente la valvola Remove and carefully clean valve Déposez et nettoyez soigneusement ...

Page 26: ...ve 91 368 CEE 93 68 CEE et qu elle est conforme aux dispositions des directives suivantes 89 336 CEE EEC 73 23 CEE EEC 93 68 CEE EEC D Lgs Executive Order Loi 277 91 NORMA RULE EN 1037 NORMA EN 982 DIRETTIVA 2000 14 CE Dlgs 19 08 05 n 187 Esecutive Order Loi Direttiva 2002 44 CE Rischi dovuti al rumore Risks due to the noise Risques dû aux bruits Rumorosità misurata a 3 mt 60dB Noise measured at 3...

Reviews: