Ingeniería de Servicio
- 68 -
Fault Codes
Fault
Code
(Hex)
Name
Description
Repair Action
13
Redun
dant
Lid
Unlock
ed
In spin mode, the lid
switch feedback has
voltage (lid closed), for
more than 5 seconds
the motor speed
feedback assumes the
basket is spinning > 4-
5 RPM when the lid
lock feedback has no
voltage (Lid
Unlocked). Lid Switch
Feedback has no
Voltage when the
BRPM is > 4-5 RPM.
Check lid switch continuity at J513 on the
control.
Check continuity of lid lock position. Opened
or Closed.
Check for proper operation of lid lock, 120
VAC while activating.
Check lid lock wiring harness from the
control to lock assembly.
If lid lock assembly and harness are OK,
replace control board.
14
Lid
Lock
Failure
Signal received by
control is indicating the
lock will not lock or
unlock when
requested or the lid
switch is indicating
open when the signal
received indicated
locked.
Verify that the lid lock is not blocked by any
external debris.
Check lid switch continuity at J513 on the
control.
Check continuity of lid lock position. Opened
or Closed.
Check for proper operation of lid lock. 120
VAC while activating.
Check lid lock wiring harness from the
control to lock assembly.
If lid lock assembly and harness are OK,
update the software.
15
Water
Temp
Sensor
invalid
1. Thermistor
disconnected/not
present.
2. Failed Thermistor
Check thermistor resistance from connector
J701 on the control board. Validate the
resistance matches the table in mini-manual.
Check wiring harness and connectors.
Replace thermistor
Summary of Contents for Kraken
Page 9: ...Ingenier a de Servicio 9 Model Graphics...
Page 36: ...Ingenier a de Servicio 36 Lift the basket out of the tub Remove the tub washer...
Page 38: ...Ingenier a de Servicio 38 Disengage the rod and spring suspension from the tub assembly...
Page 41: ...Ingenier a de Servicio 41 Bottom Component View...
Page 51: ...Ingenier a de Servicio 51 Schematic...
Page 52: ...Ingenier a de Servicio 52 Control Board User Interface...
Page 74: ...Ingenier a de Servicio 74 Cycle Overview...
Page 75: ...Ingenier a de Servicio 75 Cycle Overview...
Page 76: ...Ingenier a de Servicio 76 Cycle Overview...
Page 77: ...Ingenier a de Servicio 77 Cycle Overview...
Page 78: ...Ingenier a de Servicio 78 Cycle Overview...
Page 79: ...Ingenier a de Servicio 79 Cycle Overview...
Page 80: ...Ingenier a de Servicio 80 Cycle Overview...
Page 81: ...Ingenier a de Servicio 81 Cycle Overview...
Page 82: ...Ingenier a de Servicio 82 Cycle Overview...
Page 83: ...Ingenier a de Servicio 83 Cycle Overview...
Page 84: ...Ingenier a de Servicio 84 Cycle Overview...
Page 85: ...Ingenier a de Servicio 85 Cycle Overview...
Page 86: ...Ingenier a de Servicio 86 Cycle Overview...