Ingeniería de Servicio
- 64 -
Fault Codes
Fault
Code
(Hex)
Name
Description
Repair Action
4
Reset
Monito
r
Control is resetting
the software by itself
due to criteria it
believes could
resolve itself upon
reset.
Check for loose connections at the control.
Reconnect if any.
Check for recommended house line voltage
to the washer.
5
Mode
Shifter
Control
didn’t see the
transition from Agitate
ti Spin or vice-versa
in the time required.
Could mean the shift
didn’t occur or
Control didn’t get the
signal because of
lack of connection
Check mode shifter coupler for damage and
the ability to slide in and out freely.
Using an Ohm meter, check to ensure mode
shifter switch is in the open position.
Check resistance of mode shifter motor
(approximately 5,700 ohms)
Check for 120 VAC to the mode shifter motor
at the control J512
connector.
If voltage is present, replace the mode shifter.
If voltage is not present at the control, replace
control.
6
Critical
Flood
Level
by
Pressu
re.
Pressu
re level
exceed
s 17.5
inches
above
pressu
re port.
Control received an
extended period of
pressure readings
that is nearing over-
flow levels. Pressure
17.5”.
Voltage Output must
be present. Could
mean water did get
that high due to
briefly stuck water
valve. Voltage output
of sensor too high for
actual water level
because of sensor or
water in pressure
tube increasing
pressure.
Check pressure tube for pinches where it
goes through top cover grommet.
Check pressure tube for trapped water.
Check for any leaking water valves.
Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.
Summary of Contents for Kraken
Page 9: ...Ingenier a de Servicio 9 Model Graphics...
Page 36: ...Ingenier a de Servicio 36 Lift the basket out of the tub Remove the tub washer...
Page 38: ...Ingenier a de Servicio 38 Disengage the rod and spring suspension from the tub assembly...
Page 41: ...Ingenier a de Servicio 41 Bottom Component View...
Page 51: ...Ingenier a de Servicio 51 Schematic...
Page 52: ...Ingenier a de Servicio 52 Control Board User Interface...
Page 74: ...Ingenier a de Servicio 74 Cycle Overview...
Page 75: ...Ingenier a de Servicio 75 Cycle Overview...
Page 76: ...Ingenier a de Servicio 76 Cycle Overview...
Page 77: ...Ingenier a de Servicio 77 Cycle Overview...
Page 78: ...Ingenier a de Servicio 78 Cycle Overview...
Page 79: ...Ingenier a de Servicio 79 Cycle Overview...
Page 80: ...Ingenier a de Servicio 80 Cycle Overview...
Page 81: ...Ingenier a de Servicio 81 Cycle Overview...
Page 82: ...Ingenier a de Servicio 82 Cycle Overview...
Page 83: ...Ingenier a de Servicio 83 Cycle Overview...
Page 84: ...Ingenier a de Servicio 84 Cycle Overview...
Page 85: ...Ingenier a de Servicio 85 Cycle Overview...
Page 86: ...Ingenier a de Servicio 86 Cycle Overview...