64
Owner’s Manual
E
nglish
300 SERIES SYSTEM WIRING DIAGRAM
Page 5
54626-01_97_A
G
C
G
C
RED AC
WHT AC
T
J32
T1
SWITCHBANK A
J11
J15
J25 J63
J33
BALBOA INSTRUMENTS, INC.
VS500Z
P/N 22972 REV D
MADE IN U.S.A
COPYRIGHT 2005
S1
J6
J7
J8
U4
HTR2
HTR1
TB1
FUSE .3A 250V
FUSE 3A 250V
E.GND
CLASS G FUSE 30A
F5
F4
K6
K1
W10
K5
J23
J73
F1
J29
J20
TST
SEN. A SEN. B
W1
J1
W2
K4
K2
K3
Balboa
F2
J43
J18
TORQUE
RANGE
FOR TB1:
27-30 IN. LBS.
HO
T
BLA
CK
NEUTRAL
WHITE
HO
T
RED
G
C
FUSE 3A 250V
Black jumper required.
Do not remove.
DIP A10 must
be ON and
jumper added
for 120V systems.
Remove for
240V Systems.
4.0 kW
4.0 kW
Heater rated @ 240V
(Approx. 1kW @ 120V)
Ozone
Ozone must be same voltage as Pump 1.
Ozone runs with Pump 1 low-speed.
12V
Light
2-Spd P1
Wiring Configuration and DIP Settings
Setup 1 (As Manufactured)
s 60UMP3PEED
s 63PA,IGHT
s 6/ZONE
s 6K7(EATER!PPROXK7 6
s 6,6,OR6,5-AIN0ANEL
A1, Test Mode OFF
A2, Un, P1, TE, LT
A7, Mode changes allowed
A10, High Amp mode
A5, P1-high timeout, Table 1
A4, N/A (must be OFF)
A9, P1-low timeout, Table 1
Panel Button Assignments
1=Unused
2=Pump 1
3=Temp
4=Light
Panel Button Positions
1
2
3
4
1
4
2
3
100
59
41
SSID #
Memory
Reset
J43
A2, P1, LT, TD, TU
A2, P1, LT, TD, TU
1=Pump 1
2=Light
3=Temp Down
4=Temp Up
120 Volt Connections
240 Volt Connections
Black AC Jumpers
12 Volt Connections
Relay Control Wires
Wiring Color Key
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
Board Connector Key
1
2
3
4
WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)