52
Owner’s Manual
E
nglish
Automatic Time Outs
Your Spa is equipped with an automatic Time
Out feature designed to protect both the
equipment and the user. For your safety and
to reduce unnecessary use of the pumps and
lights, the Time Out feature turns selected
accessories off automatically, as follows:
EQUIPMENT SAFETY FEATURES
Accessory
Mode
Shuts off in...
Pump 1
Low
2 hours
Pump 1
High
15 minutes
Pump 2
High
15 minutes
Pump 3
High
15 minutes
Blower
15 minutes
Lights
1 hour
Common LCD Equipment Safety Messages
The following table describes the most common messages, possible causes, and corrective
actions you may need to take:
If the LCD
displays...
OHH
OHS
HFL
Indicates...
Overheat - one
of the sensors
has detected
water tempera-
ture of 118°F+
(48°C+) inside
the heater
Overheat
- One sensor
has detected
temperature of
spa water
entering heater
to be 110°F+
(43°C+)
Heater flow
problem
What happens...
Spa heater will
automatically
shut down until
temperature falls
below 108°F+ (42°C+)
Spa heater will
automatically shut
down until
temperature falls be-
low 108°F+ (42°C+)
Heater will shut down
while spa continues
to function normally
Possible cause...
- Low speed pump
operating for an ex
tended period of time
- Programming error
causing continuous
filtering
- Faulty Pump
- Low speed pump
operating for an
extended period of
time
- Programming error
causing continuous
filtering
- Plugged filter
- Low water
Corrective Action...
- Make sure slice valves
are open
- Reprogram to ensure
time cycles not
overlapping
- Contact dealer if
problem persists
- Open all jets
- Make sure slice valves
are open
- Reprogram to ensure
time cycles not
overlapping
- Contact dealer if
problem persists
- Open all jets
- Remove filter and clean
- Add water
- Contact dealer
- Open all jets