background image

The 

Quick Reference Card

 provides a quick overview of your spa's main

functions and the operations accessible with your digital control pad.

TSPA-MP SPA PACK

Quick Reference Card

Starting Pump 1:

Press 

Pump 1

 key to turn Pump 1 on at low speed. Press a second 

time to turn pump to high speed. A third time turns pump off. A built-in 
timer automatically turns pump off after 20 minutes, unless pump has 
been manually deactivated first.

The "Pump 1" icon lights up when Pump 1 is on at high
speed. It flashes when pump is on at low speed.

Pumps have started up for one minute on several occasions and "Filter 
Cycle" icon is flashing.

Not a bug but a feature!

Our

 Smart Winter Mode 

protects your system from the cold by 

turning pumps on for one minute several times a day to prevent water 
from freezing in pipes.

TROUBLESHOOTING

Filter cycle stops and "Filter Cycle" icon is flashing.

Not a bug but a feature!

To prevent excessive water temperature caused by too long filter 
cycles, the system will cancel a filter cycle after 3 hours if water 
temperature exceeds Set Point by more than 2˚F (1˚C).

40-minute filter cycle time-out.

If you turn a pump, blower or light on during a filter cycle, the cycle will 
be interrupted and will only resume 40 minutes after you (or the 
system) have turned the last active output off. The "Filter Cycle" icon will 
flash.

The display is flashing.

A power failure has occurred. Press any key to reset the system,
then reprogram all desired parameters.

Water temperature is flashing.

Water temperature in the spa has reached 112˚F (44˚C).

Do not enter the water! Allow the water to cool down. 
The system will reset itself when water reaches 109˚F (43˚C).

Call your dealer or service supplier if problem persists.

Starting Pump 2:

Press 

Pump 2

 key to turn Pump 2 on at low speed. Press a second 

time to turn pump to high speed. A third time turns pump off. A built-in 
timer automatically turns pump off after 20 minutes, unless pump has 
been manually deactivated first.

The "Pump 2" icon lights up when Pump 2 is on at high
speed. It flashes when pump is on at low speed.

Temperature display:

The display toggles every 5 seconds alternately showing the hourly 
time and the current water temperature.

Turning the light on:

Press 

Light

 key to turn light on at high intensity. Pressing a second and a 

third time reduces light intensity. A fourth time turns light off. A built-in 
timer automatically turns light off after 2 hours, unless light has been 
manually deactivated first.

Fiber Box Option:

 If your spa is equipped with an optional fiber box, 

press 

Light

 key once to turn fiber box (motor & light) on. Press a 

second time to turn fiber box motor off and leave light on. A third time 
turns both fiber box motor & light off. A built-in timer automatically turns 
fiber box off after 2 hours, unless fiber box has been manually deacti-
vated first.

Setting water temperature:

Use 

Warm

 or 

Cool

 arrow key to regulate water temperature. The 

temperature setting will be displayed for 5 seconds to confirm your
new selection.

The "Set Point" icon indicates the desired temperature,
NOT the current water temperature!

Water temperature can be adjusted by 1-degree increments from
59 to 104˚F (15 to 40˚C).

Economy mode:

Press 

Econo. 

key to override the Economy mode programming (see 

overleaf). The override will last until midnight.

The "Economy Mode" icon lights up when the system is
in Economy mode.

Quiet mode:

Press 

Quiet 

key to turn down pumps and blower. Simply press key to 

resume normal operations. The system will automatically return to 
Normal mode after 1 hour, unless it has been reactivated.

The "Quiet Mode" icon lights up when the system is in
Quiet mode.

Automatic water heater start:

When water temperature is 1˚F (0.5˚C) lower than the Set Point, the 
heater will automatically turn on until water temperature reaches Set 
Point plus 1˚F (0.5˚C).

The "Heater" icon lights up when the heater is on. It flashes
when there is a request for more heat but the heater has not
yet started.

A service icon is displayed.

A problem has been detected.

Do not enter the water! Check and open water valves. Clean filters
if necessary. Check water level. Add water if needed.

Shut power off and power your spa up again to reset the system.

Call your dealer or service supplier if problem persists.

Reviews: