8. Set the shower base into place and 

guide the drainpipe into the drain by using 

the handle of a hammer or similar object.
9. Level the shower base and set plumb. 

If the floor is not level, it will require the 

use of shims (not provided) to level the 

shower base. (See Figure 6)
If shims are required, they should be 

placed no more than 6 inches apart to 

provide proper support. 

DO NOT SHIM

THE UNIT MORE THAN 1/8”.

 If the 

shower base requires more than 1/8” shim 

adjustment, the shower base will need to 

be pulled out and the floor will need to be 

leveled. Ensure the drain is lined up in the 

appropriate areas.
10. Secure the shower base to the 

framing members through the flanges 

using 6D galvanized screws on 8” 

centers.
11. Place 2-50 lb. bags of concrete on the 

drain. (See Figure 8)
12. Place 1-50 lb. bag of concrete on 

threshold. (See Figure 8)
13. A 2ft level should be placed from 

floor to ensure the unit has proper slope 

and drainage. If unit does not drain 

properly, the unit must be pulled back up 

to determine where the problem lies. This 

should be done immediately after step 12 

before the materials have had a chance to 

set. (See Figure 7)
14. Unit should be walked in and found to 

be stable with minimal flex.
15. All bracing can be removed after 12 

hours after 100% silicone adhesive has 

been applied.

**THE DRAIN CONNECTION SHOULD 

BE TIGHTENED AFTER THE FLOOR 

HAS BEEN BRACED, CURED, AND 

THE BRACE REMOVED i.e. 12 HOURS

AFTER INSTALL.**

**CHECK THE FLOOR TO ENSURE 

THERE ARE NO HIGH SPOTS AND THE 

DRAFT HAS BEEN MAINTAINED. (See 

Figure 7)**

**ATTENTION: THE THRESHOLD MUST 

BE FLAT ACROSS THE FULL WIDTH 

WITH NO BOW AND LEVEL TO THE 

FLOOR.**

Following the appropriate installation 

procedures Is imperative on this 

product. Not following these

procedures could result in product 

failure which will not be covered under 

manufactures warranty.

5

2-50 lb. bags of 

concrete on drain.
1-50 lb. bag of 

concrete on 

threshold.

Pad concrete 

bags with 

drop cloth.

Figure  5

Figure 6

Figure 7

Figure 8

Summary of Contents for 106630

Page 1: ...nce only Any critical dimensions required for installation should be taken directly from the unit being installed Any independent changes made to the unit or to any options and accessories supplied wi...

Page 2: ...l directly on the sub floor and others will require a recess or pit These shower bases require special preparation of the installation site and very specific installation procedures to assure the show...

Page 3: ...ill be at the acceptable height above the finished floor An alternative to the recessed installation is to either build up the entire room floor to be even with the top of the threshold or to construc...

Page 4: ...ean the area of all dirt trash oil grease water and other contaminants that may affect adhesion 4 Apply 100 silicone caulking bead wide by high around the box out See Figure 5 5 Apply 4 100 silicone c...

Page 5: ...ensure the unit has proper slope and drainage If unit does not drain properly the unit must be pulled back up to determine where the problem lies This should be done immediately after step 12 before...

Page 6: ...oivent tre prises directement partir de l unit en cours d installation Toutes les dimensions des unit s publi es sont titre de r f rence seulement Toutes les dimensions critiques requises pour l insta...

Page 7: ...lacer le carton du carton dans le bas de la base de douche pendant l installation pour viter d endommager la surface finie Lorsque vous placez la base de douche dans l alc ve du cadre vous pouvez util...

Page 8: ...uche soit la hauteur acceptable au dessus du sol fini Une alternative l installation encastr e consiste soit construire tout le sol de la pi ce pour tre au m me niveau que le haut du seuil soit constr...

Page 9: ...t rieure et le drain Voir figure 4 REMARQUE VOUS N AVEZ PAS BESOIN DE REMPLIR L EMPLACEMENT DU DRAIN AVEC DU MAT RIAU DE LITERIE 6 Ensuite appliquez un cordon continu de calfeutrage 100 silicone de la...

Page 10: ...vide pas correctement l unit doit tre tir e vers le haut pour d terminer o se situe le probl me Cela doit tre fait imm diatement apr s l tape 12 avant que les mat riaux aient eu la possibilit de prend...

Page 11: ...la instalaci n debe tomarse directamente de la unidad que se est instalando Cualquier cambio independiente realizado a la unidad o cualquier opci n y accesorio suministrado con la unidad m s all de lo...

Page 12: ...SUJETA A LA APROBACI N DEL C DIGO Consulte las impresiones de trabajos y o consulte con el arquitecto para ver si su instalaci n debe cumplir con ADA Estas unidades de base de ducha se instalan de man...

Page 13: ...a est a la altura aceptable sobre el piso terminado Una alternativa a la instalaci n empotrada es construir todo el piso de la habitaci n para que est nivelado con la parte superior del umbral o const...

Page 14: ...a pared exterior y el drenaje Ver Figura 4 NOTA NO NECESITA RELLENAR LA UBICACI N DEL DRENAJE CON MATERIAL DE CAMA 6 Luego aplique un cord n continuo de calafateo de silicona 100 de de ancho x 3 8 de...

Page 15: ...ser jalada hacia arriba para determinar d nde se encuentra el problema Esto debe hacerse inmediatamente despu s del paso 12 antes de que los materiales hayan tenido la oportunidad de fraguar Ver Figur...

Page 16: ...ccessing product Limited warranty please visit www maax com us warranty MAAX Bath Inc offers express limited warranty on each of its products This warranty extends only to the original owner end user...

Reviews: