13
Hakki Pilke 38 Easy
Original
Version 6
When using the cardan shaft, observe any instructions provided by the shaft's manufacturer. The splitter
requires 10 kW of power, which must be taken into account with regard to the capacity of the cardan shaft.
A suitable cardan shaft is of power class four. Check that the shaft is properly locked to the splined shaft of
the angle transmission. Connect the chain that prevents the protective cover from rotating to opening B. If
necessary, the cardan shaft can be suspended from hook C. Finally, ensure that all the connections are safe
and secure. Never use a damaged or unprotected cardan shaft.
Note! Tractor-powered splitters must be attached to the tractor's lifting equipment.
Note! The starter (Figure 15) only functions when the machine is powered by electricity.
3.2.2.
Electrical drive
An electrically-powered splitter functions
with a power of 10 kW. The electric
motor IP- rating is 55. The fuse must be
at least 25 A. The electrical cable must
be at least 5 x 4 mm². In order to connect
the cable, move the protective cover B of
the socket A and angle transmission into
a position where it covers the angle
transmission.
In an electrically-powered machine, the
power cable of electric control is
connected to the socket on the side of
the machine.
The splitter can be activated with the
green button of the starter in the control
panel in the front panel of the machine.
If the electric motor rotates in the wrong
direction (i.e. the machine makes an
abnormal noise and the hydraulic
functions are inoperable), the current
phase is incorrect. We recommend using
an extension cord that allows you to
switch the current phase, or an adapter.
Note! If the extension cord does not
have a phase switch, the electrical work
related to changing the phase must be
performed by an electrician.
Figure 13. Powering the machine with electricity
Figure 14. Electrical connector for an electric control
device
Figure 15. Starter