background image

 

 

Version 5.1

 

 

15     

 

_________________________________________________________________________________

 

_________________________________________________________________________________

 

5.3 Model „TAURUS C / IRC:

 

The envelope sealing machine

 TAURUS C resp. IRC

 offers in addition an              

integrated counter.

 

 

 

 

 

 

 

 

 

 

Pulse counter with 7

-

digit LCD, 48 Hz/8 kHz with integrated lithium battery,        

without backlight.

 

 

Description of the counter

 

 

Scaling factor, factory

-

programmed

 

 

7

-

digit LCD

-

display, 8,6 mm high 

 

 

Counting range 30Hz or 1 kHz / 0..99999999, no decimal point

 

 

Data storage on internal EEPROM

 

 

DIN

-

housing 48 x 24 mm, dark

-

grey

 

 

Power supply over internal battery

 

 

Functionality 

 

When pushing the light

-

grey button on the front, the counter will be reseted. 

 

Registration of the documents resp. letters has be effected by Ultrathin Photo-

electric Sensor with Built

-

in Amplifier.

   

 

 

 

Summary of Contents for TAURUS

Page 1: ...___________________________________________________________ _________________________________________________________________________________ Envelope Sealing Machine Model TAURUS Instruction Manual E...

Page 2: ...ealing machine for envelopes up to 16mm thickness with integrated counter and stacked option for stacked envelopes Large re ceiving tray L 380mm universal input voltage 90 264VAC 50 60Hz TAURUS IR ID...

Page 3: ...nsportation moving 8 4 2 Setting up the envelope sealing machine 9 4 3 Power supply 10 5 INSTRUCTION FOR USE 11 5 1 Standard use model TAURUS 11 5 2 Models TAURUS IR IRC 12 5 3 Models TAURUS C IRC 15...

Page 4: ...41 0 44 710 40 41 hereby declares that the Envelope Sealing Machine including all its models TAURUS IR C IRC meets all the basic health and safety requirements of the Machine Directives 2006 42 EG App...

Page 5: ...4 2 DANGER WARNING CAUTION INFORMATION This means there is an immediate threatening danger When instructions have not been followed death or seri ous harm to the body invalidity can be caused This mea...

Page 6: ...specially the safety pre cautions should be respected by all who use this Envelope Sealing Machine In addition further local rules and regulations must be adhered to for accident pre vention The opera...

Page 7: ...ow 10 C or over 50 C in areas containing highly flammable material in areas with explosive material in very dirty or dusty environments in corrosive environments e g where the air has a high salt cont...

Page 8: ...sealed No manual opening of the flaps handling or pressing of the letter piles is necessary 3 2 Description of functions A large water reservoir with a controlled water level and automatic level regu...

Page 9: ...t be filled with tap water If the tank we re to tip over quickly the valve closes off the water In hard water areas add 4 to 5 drops of cleaning fluid This way you will have a equally smooth and spot...

Page 10: ...sture basin water level will slowly go down In this way the water compartment is shut off and the machine parts connected to electric power cannot come into contact 11 Take out the support pins from t...

Page 11: ...same width together place the flaps all on the same side The format slide should be positioned with an additional 2mm space around the edge of the envelope and for longer formats they should open to...

Page 12: ...e unit picture 3 4 page 14 Release knurled nut slightly and shift the separate pressure plate unit to the upper position 12 mm and fix the knurled nut again The height adjustment of basin and separate...

Page 13: ...___________________________________________________ _________________________________________________________________________________ Nested envelopes Normally stacked envelopes direction of processin...

Page 14: ...___ Adjustment of separate pressure plate unit Adjustment of basin support 8 16 mm Up to 8 mm Release knurled nut slightly and shift the separate pressure plate unit to the up per position resp slide...

Page 15: ...48 Hz 8 kHz with integrated lithium battery without backlight Description of the counter Scaling factor factory programmed 7 digit LCD display 8 6 mm high Counting range 30Hz or 1 kHz 0 99999999 no d...

Page 16: ...hen the correct water level is set also for example when replacing the mo isture tank the circular level is recorded by means of its three fixing screws and therefore the right water level is retained...

Page 17: ...se with the protective cover so that the rubber parts are not damaged by external light sun and heat sources First of all the power plug must be removed from the power point in the wall pull only on t...

Page 18: ...nd belt 5 On the front wall to the left loosen M5x20 screw and U disc M5 approximately 6 8 mm 6 On the front panel loosen first the 2 M6x16 screws on the left and right left through hole in top side p...

Page 19: ...c and knurled nut M6 on the back 6 3 Replacing the conveyor roller rubber rings Depending on the degree of wear these rubber rings of the conveyor rollers should be replaced regularly Always replace a...

Page 20: ...e free The drive has auto matic belt tension and a safety clutch If the motor drive mechanism is defective the motor or the convoyer rubber belt needs to be replaced Consult a technician or authorised...

Page 21: ...356 Rocker Switch black with on off switch and fuse holder 1 527 Permanent DC motor 24VDC 5000 RPM single worm ge ar 10 1 900 Ncm without pulley 1 529 PWM DC Power Controller 9 28V 10A max 1 530 150W...

Page 22: ...ing basin arm w short moisten ing roller and complete shaft 605 Moistening basin arm w long moisten ing roller and complete shaft 553 Flap feeding roller Partition Wall 555 Conveyor roller complete wi...

Page 23: ...C Counter integrated standard on models TAURUS C IRC Length of receiving tray 382 mm standard Max width of envelope 250 mm B5 B4 B6 5 Max thickness of package 16 mm Max sealing capacity C5 C5 6 18 000...