MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de
38
38
38
38
38
7.3 Backup on Cue Cards
The complete programs of the Lightcommander can be saved to cue cards
(ITT CANNON - STAR CARD CSC-0032K-SM-3ll or compatible ones).
UTILITY/
SETUP
BACKUP
Date and time when the card
was programmed last
B A C K U P
EXCHANGE
MEMORY
LOAD
FROM CARD
SAVE
TO CARD
CARD: 01/24/94 20:15:12 MA 48/6 V 2.00
R/W - TEST: OK
CHECKSUM: OK
Testing the card.
When using a new
card or in case of
empty batteries an
ERROR message will
be displayed
Exchanges the data
between cue card and
desk
Saves the data from the
desk to the cue card
Loads data from card and
overwrites data in the desk
ATTENTION: The cue cards work with a battery which has to be mounted
before the first use. Average lifetime of these batteries is two years. Note the
date of inserting the battery on the backside of the card and exchange the
battery in time, otherwise all programs on card get lost.
Change battery only while card is inserted - the card is supplied
meanwhile by the desk. All shows will get lost, when you remove the
battery from the card, while the card is not inserted in the desk
.
Insert the card in the desk. Release the locking device of the Battery carrier
and remove only the battery carrier. Attatch a new battery to the carrier (pay
attention to the po / -) and insert the carrier with the new battery in
the card. Move the locking device in direction of the arrow ("Lock")
The type of battery varies from manufacturer to manufacturer - whether you
find a type identification on the card or remove the battery - while card is
inserted - and identify the type of battery.
Please remove the card from the desk as long as the card is not in use.
7.4 CLEAR ALL Programs on the Desk
When starting with a new show all programs of the Lightcommander can
be cleared completely by one single operation. All four display buttons
have to be held down when switching on the desk. After confirmation by
"YES" the board will clear all programs and special setups and set the
softpatch to "1 : 1".
7.5 Automatic Test Routines
Whenever the Lightcommander is switched on it will test all programs and
settings. In case there is any memory error, the according section of data
has to be cleared by the QUIT button. If this happens repeatedly please
contact your MA dealer.
IMPORTANT !
UTILITY/
SETUP
SETUP
7.6 Adjusting Date And Time
Within the setup menu time and date can
be adjusted via encoder