background image

BT/SN/RAM 6000 Series

 

Hardware Guide

2-26

Hardware Installation

Revised 2015-07-16

SN/RAM-69xx

The length of the antenna cable may affect the signal strength. Choose the appropriate cable type and length. The 
table below provides can help pre-determine the loss to expect.

Per FCC requirements the antenna gain including cable loss must not exceed 7.5 dBi in the Cellular band, 3 dBi in 
the PCS band, 5.5 dBi for LTE Band 4, and 9 dBi in the LTE Band 17 for RF exposure purposes of 2.1091. The 
antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all 
persons. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any 
other antenna or transmitter except in accordance with FCC multi-transmitter evaluation procedures.

Installation and Verification

When installing the antenna, follow the FCC and Industry Canada guidelines and keep the following in mind:

Mount the antenna(s) at least 30 cm (12 inches) from other antennas

Do not install the antenna in a closed metallic enclosure (such as a cabinet or the trunk of a car).

Once a modem has a signal, the Signal LED indicator will start flashing according to the signal strength. Addition-
ally, the Web Interface can display the received signal strength (RSSI) on the status page. The modem should have 
at the very least one bar of signal strength.

Technology

Bands

Frequencies

Antenna Configuration

LTE

2, 4, 5, 13, 17, 25

700/850/1900 & 1700 (AWS)/

2100(AWS) MHz

MIMO Required

Fallback CDMA/EVDO

BC0, BC1, BC10

800/1900 MHz

Diversity Support

Fallback HSPA+

1, 2, 4, 5, 8

850/900/1900/2100 & 1700(AWS)/

2100(AWS) MHz

Diversity Support

Fallback GSM/GPRS/EDGE

-

850/900/1800/1900 MHz

-

Cable Type

Loss per 100 feet

8216 (RG58)

31 dB

8267 (RG213)

7.6 dB

LMR-400

3.9 dB

LMR-500

3.15 dB

LMR-600

2.5 dB

LMR-1200

1.26 dB

Summary of Contents for BT/SN/RAM 6000 Series

Page 1: ...Sixnet Series BT SN RAM 6000 Hardware Guide July 2015...

Page 2: ...cations and Pinout RAM 6000 units only 16 Modem Views 17 Indicator Lights LED 18 Data Interface Specifications Serial Ethernet USB 18 Ethernet Port 18 USB Device Port 18 Serial Port DB9 18 Serial Port...

Page 3: ...e modem 29 Testing the power connection 29 Thermal Performance and Considerations 30 Hot Operating Conditions 30 Cold Operating Conditions 31 Cleaning 31 Service and Support Information 32 This manual...

Page 4: ...designed to comply with the limits for a Class A digital device as described in the FCC Rules This equipment has been tested and found to comply with the limits for a Class A digital device pursuant t...

Page 5: ...www redlion net Publication History The following information lists the release history of this document ISSUE REVISION RELEASE DATE CONTENT DESCRIPTION August 2014 August 2014 BT SN RAM 6000 Series...

Page 6: ...peci fied by Red Lion the protection provided by the equipment may be impaired Overvoltage category II Per IEC 61010 1 Warnings Cautions Notes Warnings apply to situations where personal injury or dea...

Page 7: ...our tre responsable de l entretien de l quipement cons cutifs ou la s curit du personnel En particulier Red Lion d cline toute respons abilit pour les dommages directs ou indirects r sultant de l util...

Page 8: ...warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation maintenance misuse neglect of any cause other than ordinary commercial or industrial...

Page 9: ...0 850 1900 2100 MHz WCDMA with diversity HSDPA HSUPA HSPA Backward compatible with GPRS EDGE UMTS LTE Models See Frequency Specifications tables in Chapter 2 Programmable Platform Configurable Events...

Page 10: ...4 0W typical Transmitting 660x 2 0W 2 9W 6621 3 6W 4 5W 67xx 2 6W 6 9W 6721 4 3W 8 7W 680x 2 6W 5 0W 6821 4 2W 6 6W 690x 2 6W 6 9W 6921 4 3W 8 7W PoE Operation EB models only IEEE 802 3af compliant Po...

Page 11: ...ions may cause harmful inter ference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference to radio communications in which case the user wi...

Page 12: ...BT SN RAM 6000 Series Hardware Guide 1 12 Product Overview Revised 2015 07 16 Mechanical Specifications Mechanical Specifications Front View Note GPS antenna is only available on RAM 69xx products...

Page 13: ...BT SN RAM 6000 Series Hardware Guide 1 13 Product Overview Revised 2015 07 16 Mechanical Specifications Side View Note GPS antenna is only available on RAM 69xx products...

Page 14: ...ctor BT SN RAM 6x00 Power is supplied to the modem via the 4 pin Molex connector on the front panel for the BT SN RAM 6x00 mod els The pins are described as follows Pin Name Description 1 GND Ground 2...

Page 15: ...r input to the modem is protected against reverse polarity and over voltage The modem s power consump tion is as follows Typical Power Consumption Watts Model Standby Transmitting Minimum Transmitting...

Page 16: ...VDC Absolute Maximum VDC 33VDC Leakage IDC at 5VDC 150uADC 1x Analog Input Shared with Digital Input DIN AI1 Configuration unisolated input reference to ground Resolution 1024 ADC 10 bit VDC per step...

Page 17: ...6401 BT SN RAM 6601 SN RAM 6701 BT SN RAM 6801 SN RAM 6901 Screw block power con nector PoE power input BT SN RAM 6401EB BT SN RAM 6601EB SN RAM 6701EB BT SN RAM 6801EB SN RAM 6901EB Ethernet Switch...

Page 18: ...connector style The modems are DCE Date Communication Equipment devices and are compliant with EIA 232 standard Connect a DTE device to a DCE device using a straight pin for pin connection cable To c...

Page 19: ...signal The TX pin 3 wire is the one through which data from an attached device is transmitted to the DCE modem The RX pin 2 wire is the one on which data is transmitted by the DCE modem RTS and CTS a...

Page 20: ...D TX and RX have to be crossed between the modem DCE and the other DCE device GND is connected to GND Disable flow control on the modem and be sure that the attached device does not check for any of t...

Page 21: ...settings for older ver sions rerun the SN Reflashing procedure found at www redlion net FW Upgrade Press and hold between 10 and 15 seconds WAN LED flashes quickly Puts the modem in advanced firmware...

Page 22: ...SN 1 1 3G GSM Molex end connector cable AT AT T BM Bell Mobility AM Generic MTS Manitoba RO Rogers TE TELUS SN 6800 XX AC SN 1 1 3G GSM AC adapter SN 6800 XX MX SN 1 1 3G GSM AC adapter Molex end conn...

Page 23: ...Molex end connector cable AT AT T BM Bell Mobility AM Generic MTS Manitoba RO Rogers TE TELUS RAM 6800 XX AC RAM 1 1 3G GSM AC adapter RAM 6800 XX MX RAM 1 1 3G GSM AC adapter Molex end connector RAM...

Page 24: ...g it in place See the image at right for reference The DIN clip has an integral spring mechanism that keeps it securely attached to the rail Refer to the diagrams below for how to mount and remove the...

Page 25: ...encies Antenna Configuration CDMA EVDO BC0 BC1 800 1900 MHz Diversity Support Technology Bands Frequencies Antenna Configuration HSPA 1 2 5 6 8 800 850 900 1900 2100 MHz Diversity Support Fallback GSM...

Page 26: ...res Installation and Verification When installing the antenna follow the FCC and Industry Canada guidelines and keep the following in mind Mount the antenna s at least 30 cm 12 inches from other anten...

Page 27: ...however it is recommended and will improve throughput in low sig nal and fringe areas For SN RAM 67xx 69xx units this antenna is required for compliance with LTE MIMO opera tion To get the best perfo...

Page 28: ...o Type B mini plug USB cable for the BT SN RAM 6000 series modems In order for the USB connection to work you need to install the Sixnet RNDIS USB driver which is available at www redlion net Paramete...

Page 29: ...this manual Power Source IMPORTANT Any installations involving electrical wiring and connections should be done by someone who is experienced in this field As described in the Power specifications an...

Page 30: ...en operating above 60 C The above ratings are based on moderate wireless communications If your wireless communications is atypi cally high or frequent then the maximum ambient operating temperature m...

Page 31: ...perly installed in an enclosure that protects them from direct exposure to the elements These units are not rated for outdoor installation without protection Please note that when operating below 30 C...

Page 32: ...the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in t...

Reviews: