BT/SN/RAM 6000 Series
Hardware Guide
2-24
Hardware Installation
Revised 2015-07-16
Chapter 2
Hardware Installation
Mounting the BT/SN/RAM 6000 Series Modem
There are three different ways to mount a BT/SN/RAM 6000 series modem:
•
Horizontally using two #6 screws pan or fillister head onto its horizontal mounting feet
•
Vertically using two #6 screws pan or fillister head onto its vertical mounting feet
•
Vertically using a DIN rail clip
Note:
Allow enough room to route the Ethernet, serial, I/O and other cables.
DIN Rail Mounting & Removal
The BT/SN/RAM 6000 series has a DIN rail clip pre-mounted to the back of the unit. To panel
mount the unit, the clip can be removed easily by removing the three (3) screws holding it in
place. See the image at right for reference.
The DIN clip has an integral spring mechanism that keeps it securely attached to the rail. Refer
to the diagrams below for how to mount and remove the unit to a standard EN50022 DIN rail.
Note: For best performance it is recommended that a DIN rail spacer (such as an end clamp) be used between the
RTU and adjacent devices. This will leave an air gap for best heat dissipation off of the case.
Mounting Instructions
Removal Instructions
Recommended DIN rail mounting steps:
1. Hook the top back on the DIN rail clips on the unit over the DIN
rail.
2. Push the bottom of the unit towards the DIN rail unit it snaps
into place.
Recommended DIN rail removal steps:
A. Push the whole unit down to free the bottom of the DIN rail clip.
See blue circle areas.
B. Pull the bottom of the unit away from the DIN rail.
C. Unhook the top of the unit and remove it from the DIN rail.