background image

R7C-YV4

EM-7801-AD  P. 4 / 9

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

2

3

4

1

5

10

7

8

9

6

4

5

6

7

1

2

3

3 (.12)

5.5 (.22)

7–M3 SCREW

TERMINALS

for CC-Link, POWER

10–M3 SCREW 

TERMINALS

for OUTPUT

6 (.24)

50 (1.97)

6 (.24)

18.5 (.73)

115 (4.53)

DIN RAIL

35mm wide

[5 (.20)]

30 (1.18)

54 (2.13)

17 (.66)

 

CONNECTION DIAGRAM

4

7

6

3

2

5

1

V (–)

U (+)

FG

SLD

DG

DB

DA

OUTPUT 0

In order to improve EMC performance, bond the FG
terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.

7

V0

2

COM0

8

3

V1

COM1

OUTPUT 1

9

4

V2

COM2

OUTPUT 2

10

5

V3

COM3

OUTPUT 3

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for R7C-YV4

Page 1: ...OPERATIONAL RANG Locate the power input rating marked on the product and confirm its operational range as indicated below 24V AC rating 24V 10 50 60Hz approx 180mA 24V DC rating 24V 10 approx 90mA GEN...

Page 2: ...ss Setting x10 BAUD RATE Baud Rate is selected with the rotary switch 5 4 3 2 1 0 9 8 7 6 Baud Rate Setting 0 156 kbps 1 625 kbps 2 2 5 Mbps 3 5 Mbps 4 10 Mbps OPERATING MODE Factory setting Output at...

Page 3: ...addressed to the station due to noise interference Missing parts of the data sent from the master ON OFF OFF OFF OFF Unable to receive data due to wire breakdown ON OFF ON OFF ON OFF Faulty Baud Rate...

Page 4: ...LS for OUTPUT 6 24 50 1 97 6 24 18 5 73 115 4 53 DIN RAIL 35mm wide 5 20 30 1 18 54 2 13 17 66 CONNECTION DIAGRAM 4 7 6 3 2 5 1 V U FG SLD DG DB DA OUTPUT 0 In order to improve EMC performance bond th...

Page 5: ...ON Unused Unused Unused Unused RWrn 0 1 2 3 Analog output 0 Analog output 1 Analog output 2 Analog output 3 RWwn 0 1 2 3 Interval timed Response X Refresh Data Y ANALOG OUTPUT I O DATA DESCRIPTIONS 0...

Page 6: ...hick cable to maintain low imped ance at high frequency Use shielded cables for the signals taken out of the control panel Choose a thick and short cable to ground the FG terminal of the R7C module to...

Page 7: ...he panel cover with an earth strap grounding may be strengthened and EMC may be improved Ground the control panel at low impedance using e g braided wires Keep the opening for ventilation as small as...

Page 8: ...s are illustrated in the next page Keep cables as short as possible It prevents noise emissions from the cables and noise overlapping to the cables Attach a ferrite core to reduce noise impact to the...

Page 9: ...Keep the cable as short as possible To external apparatus Shielded Cable Earth Clamp Remove a part of the shielded cable cover and ground it to the internal panel plate using an earth clamp To connect...