background image

R3-NC2

P. 7 / 7

EM-842 Rev.8

M-SYSTEM WARRANTY

M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such 
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive 
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this 
warranty.  To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original 
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR 
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

PARAMETERS SETTING BY PLC PROGRAM  

The ladder diagram below shows a program example assuming that the master station’s first I/O number is X/Y20 to 3F.
For detailed information, refer to users manuals for the PLC CPU and the Master Unit. 

X0020

Only when required

Number of connected 

*

1

modules
Number of retries

Number of automatic

return modules

Operation specification

when the CPU is down

Reserved

station

specification

X002F

M0

M1

PLS      M0

SET      M1

RST     M1

MOV                  D0

MOV                  D1

MOV                  D2

T0     H0002     H0001     D0     K3

T0     H0002     H0006     D3     K1

MOV                  D3

M1

MOV                D13

MOV                D    

T0     H0002     H0020     D13     K    

M1

MOV                  D4

MOV                  D5

MOV                  D6

MOV                  D7

MOV                  D8

MOV                  D9

MOV                D10

MOV                D11

T0     H0002     H0010     D4     K8

Invalid 

station

specification

Station information

(set for the number of

connected modules.)

 

*

2

*

1.

*

2.

Two (2) remote devices for four stations each must be assigned for 

one R3-NC2 to the host PLC.

One R3-NC2 takes two consecutive remove device stations occupying

four stations each.  Set these fields for two stations.

[MOV  14mm   D13]

[MOV  14nn     D14]

mm = R3-NC2 node address, nn = R3-NC2 node a 4

Summary of Contents for R3-NC2

Page 1: ...metal particles are present in the air install the unit inside proper housing with sufficient ven tilation Do not install the unit where it is subjected to continuous vibration Do not subject the uni...

Page 2: ...SW2 ON 8 7 6 5 4 3 2 1 SW3 ON 4 3 2 1 ON 8 7 6 5 4 3 2 1 SW1 Functions 1 2 3 4 5 6 Terminal Block Configuration Jack 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 FG SLD DG DB DA Node A...

Page 3: ...re size 0 75 1 25 mm2 3 2 13 dia 4 min 16 12 47 max 6 max 24 3 12 max COMMUNICATON CABLE CONNECTIONS DA DB DG SLD FG MASTER UNIT DA DB DG SLD FG R3 NC2 DA DB DG SLD FG I O UNIT TERMINATOR blue white y...

Page 4: ...ATA The figure below shows the allocation of the data sent from the network module to the master INPUT DATA The figure below shows the allocation of the data sent from the master to the network module...

Page 5: ...US4 out of 10 to 110 the other types out of 15 to 115 sta tus for each module The bit corresponding to such modules turns to 1 RX n 3 through RX n 6 are unused RX n 8 through RX n 14 are unused RX n 7...

Page 6: ...TA models R3 RS4 TS4 and US4 16 bit binary data With C temperature unit raw data is multiplied by 10 For example 25 5 C is converted into 255 With F temperature unit the integer section of raw data is...

Page 7: ...L INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER M System Co Ltd 5 2 55 Minamitsumori Nishinari ku Osaka 557 0063 JAPAN Phone 06 6659 8201 Fax 06 6659 8510 E mail info m system co jp PARAMETERS...

Reviews: