background image

MSP4 / MSP5 / MSP6

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-4854  Rev.15  P. 3 / 8

COMPONENT IDENTIFICATION

Power Input PCB (for AC power)

Insulation Barrier

Control PCB

Motor

Position Sensor

O-Ring

Cable Connector

Nut

Screw

Seal Spring

Output Stem

Cable

Figure 1. MSP4 & MSP5 Component Identification

Note: Construction of the MSP4 is partly different from the
above figure.

Figure 2-2. Long-life Potentiometer (MSP6)

Cable

Cable Connector

Nut

Screw

Seal Spring

Output Stem

Motor

Power Input PCB (for AC power)

Potentiometer

Control PCB

Packing

Figure 2-1. MSP6 Component Identification

OFF

1
2
3
4

ON

PWR INP ALM

DLY

ZERO SPAN DZ

SW1

Insulation Sheet

Fuse

Connector

ZERO
SPAN
DZ
DLY
SW1

PWR
INP
ALM

: Zero Adjustment
: Span Adjustment
: Deadband Adjustment
: Restarting Timer
: Direct/Reverse Actions,
  Operation at Abnormally Low Input
: Power Indicator (Green LED is ON while power is supplied)
: Input Indicator (Green LED is ON while normal signal is input)
: Status Indicator 
  (Red LED blinks at intervals of: 2 sec. in normal operation; and
   0.5 sec. when an overload (lock) is detected)

Figure 3. MSP Control PCB Identification

Note: DO NOT manipulate the adjusters with a torque exceeding their 

tolerance,or it may destroy their stoppers.
Turn them carefully and stop where they hit the stoppers.
Pay extra attention when manipulating the Restarting timer adjuster.

Summary of Contents for MSP4

Page 1: ...264V 47 66 Hz approx 25VA 24V AC rating 24V AC 10 47 66 Hz approx 25VA MSP6 24V DC 24V rating 10 approx 0 6A Built in power fuse 250V 1A rating time delay A rush current 1 5 times as high as the abov...

Page 2: ...SP stops supplying power to the motor and the status LED blinks at 0 5 sec intervals The protection can be reset by applying an input signal to move the output stem in the opposite direction or turnin...

Page 3: ...Packing Figure 2 1 MSP6 Component Identification OFF 1 2 3 4 ON PWR INP ALM DLY ZERO SPAN DZ SW1 Insulation Sheet Fuse Connector ZERO SPAN DZ DLY SW1 PWR INP ALM Zero Adjustment Span Adjustment Deadb...

Page 4: ...10 MSP5 3 50 10 20 MSP6 3 58 10 20 MSP6 4 78 20 40 MANUAL OPERATION FUNCTION for MSP4 MSP5 with AC power supply 1 Be sure to turn OFF the power voltage Operation with power voltage being applied may r...

Page 5: ...ing M Systems s yoke set model YSS for Japan sales only refer to Instruction Manual NM 4893 of the yoke set for the installation procedure MSPx Bolts M5 Position Indicator Yoke Lock Nut Output Stem Va...

Page 6: ...to stop turning as soon as they hit the stoppers ADJUSTMENT PROCEDURE A Zero and Span Supply power voltage to the MSP and apply 0 100 input Turn Zero adjuster to adjust the lower end or fully extended...

Page 7: ...HOW TO PROCEED Stem operation Apply input 0 50 100 then back to 50 0 Check that the actuator operates and positions cor rectly at each input value Repair or calibrate the unit Abnormal sound Check if...

Page 8: ...supply Check the connector and connecting section Abnormal power voltage Check the power supply Fuse melted Replace the fuse ON ON Malfunction by noise Turn off the power supply and restart Low power...

Reviews: