MECHATROLINK-III COMMUNICATION

Transmission cycle

: 125 µsec., 250 µsec., 500 µsec., 1 – 64 msec. (with 1 msec. increments)

Communication cycle

: 125 µsec. through 64 msec.

Applicable profile

:  Standard I/O profile (cyclic communication)  

 

Event-driven communication acquiring ID profile (event-driven communication)

Transmission bytes

: 16 bytes

Station address

: 03H through EFH (set with rotary switches)

Cyclic communication

: Available

Event-driven communication

: Available

Slave monitoring

: None

MECHATROLINK-III RELATED COMMANDS

Commands available with this unit are the following.

PROFILE

COMMAND

CODE

FUNCTION

Common command

NOP

00H

No operation command

ID_RD

03H

Read ID command

CONFIG

04H

Setup device command

ALM_RD

05H

Read alarm or warning command

ALM_CLR

06H

Clear alarm or warning command

CONNECT

0EH

Establish connection command

DISCONNECT

0FH

Release connection command

Standard I/O profile

DATA_RWA

20H

Transmit I/O data

• NOP (00H)

Does nothing except sending back current status

BYTE

COMMAND

RESPONSE

REMARKS

0

NOP (00H)

NOP (00H)

No operation command

1

00H

00H

Not used

2

CMD_CTRL

CMD_STAT

Refer to CMD_CTRL/CMD_STAT.

3

≥ 4

00H

00H

Reserve

• ID_RD (03H)

Reads the product ID.

BYTE

COMMAND

RESPONSE

REMARKS

0

ID_RD (03H)

ID_RD (03H)

Read ID command

1

00H

00H

Not used

2

CMD_CTRL

CMD_STAT

Refer to CMD_CTRL/CMD_STAT.

3
4

ID_CODE

ID_CODE

Refer to ID_CODE

5

OFFSET

OFFSET

OFFSET: designates the place to read data

6

SIZE

SIZE

SIZE: specify the size of data to read

7

≥ 8

00H

ID

Product’s ID

• CONFIG (04H)

No parameter to set for this unit.  Immediately response with completion.

BYTE

COMMAND

RESPONSE

REMARKS

0

CONFIG (04H)

CONFIG (04H)

Setup device command

1

00H

00H

Not used

2

CMD_CTRL

CMD_STAT

Refer to CMD_CTRL/CMD_STAT.

3
4

00H

00H

Recalculation of parameters and set up.  Other than 00H is 
not supported.

≥ 5

00H

00H

Reserve

Summary of Contents for MECHATROLINK R7K4FML3-6-DAC32B

Page 1: ...on the product and confirm its operational range as indicated below 24V DC rating 24V 10 100mA GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and I O signal for s...

Page 2: ...on at MECHATROLINK III LNK2 is established STATION ADDRESS Station Address is selected between 03H and EFH in hexa decimal The SA1 switch determines the MSD while the SA2 switch does the LSD of the a...

Page 3: ...0 29 Y1 30 31 21 22 Y3 Y5 Y2 Y4 Y14 NO ID FUNCTION NO ID FUNCTION 19 V Out Common 28 V External excitation 20 Y0 Output 0 29 Y1 Output 1 21 Y2 Output 2 30 Y3 Output 3 22 Y4 Output 4 31 Y5 Output 5 23...

Page 4: ...IONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch DIN RAIL 35mm wide 4 16 50 1 97 3 5 14 5 2 210 8 27 220 8 66 235 9 25 47 1 85 45 1 77 6 36 M3 SCREW TERMINALS FOR I O 6 7...

Page 5: ...n 1 10 X0 COM X15 NPN Connection 1 10 X0 COM X15 COM COM 19 23 28 20 24 22 25 31 26 27 32 30 33 29 34 35 36 21 V V Y18 Y20 Y22 Y24 Y26 Y28 Y30 Y17 Y31 Y19 Y21 Y23 Y25 Y27 Y29 Y16 2 18 Output Connectio...

Page 6: ...or warning command ALM_CLR 06H Clear alarm or warning command CONNECT 0EH Establish connection command DISCONNECT 0FH Release connection command Standard I O profile DATA_RWA 20H Transmit I O data NOP...

Page 7: ...CMD_STAT 3 4 0000H 0000H Clear current alarm or warning Other than 0000H is not available 5 6 00H 00H Reserve CONNECT 0EH Starts communication with master station BYTE COMMAND RESPONSE REMARKS 0 CONN...

Page 8: ...ent from the slave to the master are set in the response With output data read back CH0 IN LO CH0 data low 8 bits Bit 0 through 7 of input data are set CH0 IN HI CH0 data high 8 bits Bit 8 through 15...

Page 9: ...LO CH2 data low 8 bits Not used CH2 OUT HI CH2 data high 8 bits Not used CH3 OUT LO CH3 data low 8 bits Not used CH3 OUT HI CH3 data high 8 bits Not used CMD_CTRL CMD_CTRL command area is following BI...

Page 10: ...125 sec 17H Max Transmission Cycle 4 Yes 0x0061A800 64 msec 18H Increments of Transmission Cycle 4 Yes 0x00000001 Available to 31 25 62 5 125 250 500 sec 1 64 msec 1 msec increments 19H Min Communica...

Page 11: ...N Phone 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp EM 7773 E Rev 3 P 11 11 I O DATA DESCRIPTION DISCRETE I O MODULE 0 15 Input 0 Input 1 Input 2 Input 3 Input 15 0 OFF 1 ON Input 7 I...

Reviews: