FLOWCHART

Monitor Mode

Contents

Set Up Transmitter

Input

User Unit Setting

Calibration

Fine Adjustment

Scaling

Unit

Linearizer

Linear

(no linearization)

Alarm Value

Trip Operation

Coil at Alarm

Alarm

Set Values

(L1, L2, L3, L4)

Decimal Point

Select

0 : 9999   1 : 999.9

2 : 99.99  3 : 9.999

Set 0%, Set 100%

Set in %

0.00 to 99.99%

Set 0%, Set 100%

0 – 20mA

Zero : -99.99 to +99.99%

Span : 0.000 to 9.999

Set 0%, Set 100%

Selectable 

from -9999 to 9999

Enter input value in

scaled range.

Unit : Scale unit

Select

(L1, L2, L3, L4)

Hi or Lo alarm trip

Energize or De-energize

Select

(L1, L2, L3, L4)

Set 0%, Set 100%

Selectable 

from -9999 to 9999

Linearization Table

X : Input %

Y : Linearized value

Max. 128 points

Select

(A, mA, V, mV, W,

mW, %, °C, °F, W, Pa,

kPa, MPa, User Unit)

Parameter Protection

Setting

Lock : Protect

Unlock : Not protect

Low Cut

User Table

(linearization)

Square Root (sqt)

A

B

Summary of Contents for M7EASDY

Page 1: ...nts Failure to observe these re quirements may invalidate the CE conformance The actual installation environments such as panel con figurations connected devices connected wires may af fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE...

Page 2: ... one Use a minus screwdriver to tighten the screw DIN Rail 35mm wide Spring Loaded DIN Rail Adaptor DIN RAIL MOUNTING Set the base socket so that its DIN rail adaptor is at the bottom Position the upper hook at the rear side of base socket on the DIN rail and push in the lower When removing the socket push down the DIN rail adaptor utilizing a minus screwdriver and pull WALL MOUNTING Refer to EXTE...

Page 3: ... COM N C N O COM 10 11 6 9 3 7 8 5 L4 OUTPUT L1 OUTPUT COM L3 OUTPUT L2 OUTPUT COM 6 9 3 7 8 5 L4 OUTPUT L1 OUTPUT COM L3 OUTPUT L2 OUTPUT COM Output Code 5 SPDT Relay Output Code 2 N O Relay Output Code 3 N C Relay CONFIGURATOR JACK CONFIGURATOR JACK 4 1 2 2 WIRE TRANSMITTER V 1 5V DC MONITOR 4 1 2 2 WIRE TRANSMITTER V 1 5V DC MONITOR When 24V DC is Not Used U V POWER U V POWER 50Ω 200Ω No Connec...

Page 4: ...Input Value Down Used to switch the output display informa tion when the input display information is set to Scaled Range Value Coil Trip Action Alarm Setpoints In Coil Trip Action mode symbols mean the following E Energize D De energize High alarm trip Lo alarm trip PARAMETER LOCK The M7EASDY starts operating in the Monitor Mode with the Parameter Lock when the power supply is turned on In order ...

Page 5: ... 4 Use Up Down buttons to choose an X value 7 5 to 107 5 and press Set button 5 Use Up Down buttons to choose a corresponding Y value from 9999 to 9999 and press Set button 6 Press Mode button to save the setting and exit the Lin earizer setting ALARM SETTING Alarm Setpoints 1 Choose Alarm from the Set Up Transmitter and press Set button 2 Choose Setting Value and press Set button 3 Use Up Down bu...

Page 6: ...ode and press Set button 2 Use Up Down buttons to choose either On Off or Off Timer and press Set button 3 If Off Timer is selected specify also a time before the backlight is off from 1 to 3600 seconds 4 Press Mode button to save the setting and exit the Back Light setting Whatever is this setting a red backlight is maintained while the unit is in alarm conditions INFORMATION MODE Press Mode butt...

Page 7: ...oint Select 0 9999 1 999 9 2 99 99 3 9 999 Set 0 Set 100 Set in 0 00 to 99 99 Set 0 Set 100 0 20mA Zero 99 99 to 99 99 Span 0 000 to 9 999 Set 0 Set 100 Selectable from 9999 to 9999 Enter input value in scaled range Unit Scale unit Select L1 L2 L3 L4 Hi or Lo alarm trip Energize or De energize Select L1 L2 L3 L4 Set 0 Set 100 Selectable from 9999 to 9999 Linearization Table X Input Y Linearized va...

Page 8: ... L3 L4 Select Disable Enable Setting 0 to 100 Select On Off Off Timer Off Time Setting xxxx sec Back Light Contrast LCD Mode Property Latching Hysteresis deadband Moving Average Alarm ON Delay Timer Power ON Delay Timer Display Selectable from 0 to 99 Selectable from 0 to 999 Selectable from 0 to 3600 Enter input value in scale MODEL Complete model number FIRMWARE Version No SER NO Serial number T...

Page 9: ...he maxi mum For maximum relay life with inductive load exter nal protection is recommended 0 50 100 Input LL L HH H L2 5 7 L3 5 8 L4 3 9 L1 3 6 ON ON OFF ON ON OFF OFF OFF Example Quad N O contacts LL L H HH Alarm Trip Operation Terminal No in parentheses Trip operation in power failure Output code 2 All relays turn OFF Output code 3 All relays turn ON Output code 5 Terminals 3 9 5 8 turn ON MAINT...

Reviews: