73VR21BLD  USERS MANUAL  EM-7395-C Rev.7

73VR21x PC CONFIGURATOR

Software model: 73VR21BLD

Users Manual

http://www.m-system.co.jp/

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Tel: +81-6-6659-8201      Fax: +81-6-6659-8510

E-mail: [email protected]

Summary of Contents for 73VR21 Series

Page 1: ...AL EM 7395 C Rev 7 73VR21x PC CONFIGURATOR Software model 73VR21BLD Users Manual http www m system co jp 5 2 55 Minamitsumori Nishinari ku Osaka 557 0063 JAPAN Tel 81 6 6659 8201 Fax 81 6 6659 8510 E mail info m system co jp ...

Page 2: ...E 8 2 2 6 SCREEN SAVER 8 2 2 7 IP ADDRESS SUBNET MASK DEFAULT GATEWAY 8 2 2 8 TOUCH PANEL BEEP 8 2 3 DATA STORING METHOD 9 2 3 1 STORING INTERVAL 9 2 3 2 STORING SETTING 9 2 4 DISPLAY SETTING 13 2 4 1 CHART SPEED 13 2 4 2 GRAPH DIRECTION 13 2 4 3 DIGITAL DISPLAY TYPE 13 2 4 4 DIGITAL DISPLAY 13 2 4 5 DATA FILE USED VOLUME SETTING 13 2 4 6 DISPLAY PEN NUMBER 14 2 4 7 DISPLAY PEN NUMBER OV 14 2 4 8 ...

Page 3: ... 12 ALARM SETTING BUNDLE 26 2 13 SELECT DISPLAY PENS 27 2 14 HARDWARE CONFIGURATION 27 3 FILE OPERATION 28 3 1 READ SETTING FILE 28 3 2 WRITE SETTING FILE 28 3 3 CONVERTING OLD VERSION SETTING FILES 28 3 4 EXPORT SETTING TO CSV 28 3 5 CREATE CF DATA 29 4 ONLINE OPERATION 30 4 1 UPLOAD 30 4 2 DOWNLOAD All 30 4 3 DOWNLOAD Runtime 30 4 4 REMOTE START STOP 31 APPENDIX A SETTING FILE FORMAT IN CSV 32 A...

Page 4: ...tion remotely Creating a data file Creating a data file in a CF Card Exporting configurations to CSV Configuration files created on the 73VR21BLD can be converted into CSV format 1 2 SYSTEM REQUIREMENTS The PC environment indicated below is recommended for use with the 73VR21BLD OS Windows 7 Professional 32 bit or Windows 10 32 bit 64 bit Note Proper software functions may not be ensured under cer...

Page 5: ...21x can communicate through Ethernet The 73VR21x must be setup with an IP address in advance Please refer to the 73VR21x Users Manual to set the IP address n ETHERNET CABLE TYPE When connecting the PC and the 73VR21x via a switching hub use Straight type cables When the 73VR21x is directly connected to the PC use a Reverse interlink type cable We recommend that you will choose connection with stra...

Page 6: ...urator window shown in the figure below will appear To terminate the program press the Close button X on the right top of the window Figure 1 5 Initial view In order to quit the window click Close button at the right bottom Caution DO NOT change the 73V21x configuration while the FTP convert command is executed on the 73VR Data Viewer model 73VRWV Card Reader CF Card PC Configurator model 73VR21BL...

Page 7: ...e among the following options DEMO Demonstration mode You can run the 73VR21x program without actual signal input for learning evaluation and demonstration when you choose DEMO Normal Running mode Choose this option when you connect actual input signals to the 73VR21x 2 2 2 TEMPERATURE UNIT Choose among the following options Centigrade Centigrade Celsius Fahrenheit Fahrenheit 2 2 3 START MODE Choo...

Page 8: ...er Screen saver time setting Selectable range 0 to 99 minutes The screensaver function is deactivated with the time set to zero 0 2 2 7 IP ADDRESS SUBNET MASK DEFAULT GATEWAY In order to connect the 73VR21x to a PC via Ethernet when using the 73VR21BLD Builder set an appropriate IP address Enter the IP address assigned to the 73VR21x IP address Factory default setting 192 168 0 1 The subnet mask a...

Page 9: ... interval setting is changed previously stored data are overwritten with new data 2 3 2 STORING SETTING There Five 5 storing modes as explained below No storing No recording Data is plotted on the chart or displayed on the digital meter or bargraph but no data is stored in the CF Card Normal Normal storing mode Recording is manually initiated and stopped Data is con tinuously stored while the reco...

Page 10: ... Value Threshold Data is stored while the trigger input signal value is equal to or lower than the threshold setpoint n Trigger Conditions for Discrete ON Data is stored while the trigger input signal logic is ON OFF Data is stored while the trigger input signal logic is OFF How to Set the Remote Trigger Recording Figure 2 3 2 Remote trigger setting analog Figure 2 3 2a Remote trigger setting disc...

Page 11: ...g pulse edge Data recording is initiated at a rising edge of the trigger input pulse Down Sinking pulse edge Data recording is initiated at a sinking edge of the trigger input pulse How to Set the Event Recording Figure 2 3 2b Event recording setting analog Figure 2 3 2c Event recording setting discrete 1 Storing setting Pull down the arrow to the right of Storing Field and select Event recording ...

Page 12: ... Specified Choosing the Time Specified recording on the Data storing method view changes the subsequent menu items to those suitable for the storing mode 2 Specify when you want to start recording Date time and the time duration Storing hours min With Every day setting Date is not indicated Date and or time Specify date and or time to start recording Storing hours min Specify time duration of a re...

Page 13: ... chart in the perpendicular direction or the horizontal direction Choose among the following options Perpendicular Perpendicular direction Horizontal Horizontal direction 2 4 3 DIGITAL DISPLAY TYPE Choose among the following options Tag Value The momentary value and the tag name of the data plotted on the screen Tag The tag name of the data plotted on the screen Value The momentary value of the da...

Page 14: ...ted 2 4 9 CHART COLOR You can specify different color and style for the chart Choose among the following options Gradation 1 Gradation 2 Plain Light Plain Dark Plain White 2 5 ERROR OUTPUT When the error output setting is enabled the 73VR21x outputs an alarm contact at the alarm output terminal 1 Choose Enable or Disable When Enable is selected the following selections appears 2 Contact logic Spec...

Page 15: ...atic comment entry Threshold Specify the threshold value for analog trigger signal Threshold Max 6 digits including a decimal point and minus sign Condition For analog trigger signal the following conditions can be used to trigger the comment entry Value Threshold The comment is written in when the subject pen signal goes above the analog trigger signal value Value Threshold The comment is written...

Page 16: ...tte Line thickness This setting is selectable even during recording Normal Normal line 1 pixel Thick Thick line 3 pixels Decimal place Specify how many decimal places you want to show on the digital indicators and the scale Choose among 0 1 2 and 3 For a temperature input only 0 or 1 is selectable Plot range with decimal place on the scale Plot range in an engineering unit can be indicated on the ...

Page 17: ... display range on the chart when Normal is selected at Normal Log Log s detailed setting includ ing the display range is conducted in the Exp scale Set up the upper and lower display range values It is usually the same as the engineering unit range but is set to a different range when you want to enlarge a part of the range to view details e can be used to input an exponential value such as 1e9 En...

Page 18: ...20 212 3308 R 50 1760 58 3200 S 50 1760 58 3200 C WRe 5 26 0 2320 32 4208 N 270 1300 454 2372 U 200 600 328 1112 L 200 900 328 1652 P Platinel II 0 1395 32 2543 RTD input JPt 100 JIS 89 200 510 328 950 Pt 100 JIS 89 200 660 328 1220 Pt 100 JIS 97 IEC 200 850 328 1562 Pt 50 Ω JIS 81 200 649 328 1200 Ni 508 4 Ω 50 280 58 536 Ni 100 80 260 112 500 Ni 120 80 260 112 500 Ni Fe 604 200 200 328 392 Pt 20...

Page 19: ...put 11 for the 73VR2110 Input 13 for the 73VR2112 is used Figure 2 7 2a Detailed setting discrete OFF Description ON Description Short description for ON 1 and OFF 0 status can be specified OFF description Max 5 characters ON description Max 5 characters 2 7 3 CHANNEL SELECTOR BUTTONS These control buttons are commonly used in many windows Figure 2 7 3 Channel selector buttons Function pens Previo...

Page 20: ...e right in the same window shown in Figure 2 8 Figure 2 8 Function pen setting Individual 2 8 1 COMMON SETTING Enable Disable Enable Disable the recording The pen s function data is stored when this selection is set to Enable Tag name Tag name Max 8 characters Unit Unit Max 4 characters Color Choose a desired color from the palette Line thickness Normal Normal line Thick Thick line Decimal place S...

Page 21: ...hold max Maximum value hold Peak hold min Minimum value hold Filter First order lag Time constant is a response time for a step input 0 to 100 to reach 63 Moving average Multiple samples of input data are averaged F value calculation Typically used to calculate the sterilization or disinfection time in predefined conditions Anemoscope Direction corresponding to measured data is displayed in the di...

Page 22: ... no data is recorded for the first operating cycle Coefficient K Constant A For AND OR NOT XOR functions no coefficient or constant is selectable Coefficients Constants Max 6 digits including a decimal point and minus sign Initial value Initial value is used in the function operation cycle as default data sample when last data is specified in an equation If you do not need leave the field blank Fo...

Page 23: ...ger input specify None Reset by analog input Click the right arrow to choose between Value Threshold and Value Threshold To disable the resetting by analog input specify None With one of the conditions selected choose also Input 2 tag name and the threshold value In order to avoid fre quent start reset operations due to instable analog input signal around the threshold value specify also a deadban...

Page 24: ...at is judged as a normal state so that relevant data is continuously plotted Consequently while a pen you have set up is within this range it means a corresponding input signal is in the normal state Zone Color 3 You can apply specific colors to represent each zone divided by the limits for use in the Display views Use the color palette NOTE 256 colors are used in the 73VR21x If you choose a color...

Page 25: ... not trigger alarm because the duration is shorter than the delay time True contact status starts at a point but an alarm is triggered only at b point after the delay time T has been elapsed False contact status starts at c point but the alarm is reset only at c point after the delay time T has been elapsed Color You can apply specific colors to represent each status for use in the Display views U...

Page 26: ...PY ONE PEN SETTING TO ANOTHER 1 Click on the leftmost cell you want to copy 2 Click on the right mouse button Copy option appears and click on it 3 Click on the cell you want to paste the setting on 4 Click on the right mouse button Copy and Paste options appear and choose Paste 2 11 FUNCTION PEN SETTING BUNDLE In order to review and set all function pens at once click Function Pen Setting Bundle ...

Page 27: ... field and choose among the options in the pulled down menu Number of pens that each group Page on the 73VR21x screen can show depends upon the Display pen number setting Figure 2 13 Select display pens 2 14 HARDWARE CONFIGURATION ADC Speed and Line Noise Filter type are specified With 100 msec storing intervals these settings are not neces sary ADC SPEED Choose among Low Medium and High LINE NOIS...

Page 28: ...BLD for the 73VR21x the file name must be 73VR VRP21 3 3 CONVERTING OLD VERSION SETTING FILES Setting files saved in old version builders can be converted into the latest version one so that they can be used with the 73VR21x of the latest version 1 Choose Read Setting File and open the old version file It is converted into the setting file compatible with the 73VR21BLD you are using now 2 Choose W...

Page 29: ...pecify a file name and save 3 5 CREATE CF DATA The 73VR21x automatically creates a data area dedicated to store data files when it starts up It can also be created on the PC using the 73VR21BLD Be sure to create a data file in a CF Card before trying to replace CF Cards while the 73VR21x is running Press Create CF Data and the window shown in Figure 3 5 appears on the screen Enter the drive ID whe...

Page 30: ...e ex ecuted only while recording is stopped If there were changes for the following parameters in the new configuration the data file the alarm history and the comment history files are all reset Storing interval Data format Number of enabled pens 4 3 DOWNLOAD Runtime The following parameters runtime programmable items can be downloaded even while recording System Screen saver Touch panel beep Dis...

Page 31: ... remotely start stop the 73VR21x with these control buttons When you need to change and download set tings the 73VR21x can be stopped at any time If you have set up a password to allow access the 73VR21x the Enter Password dialog box will appear Enter password and click OK ...

Page 32: ...Row A System item names Row B System parameters Row A Data storing method item names Row B Data storing method parameters Row A Display setting item names Row B Display setting parameters Row A Error output item names Row B Error output parameters Row A Hardware configuration item names Row B Hardware configuration parameters ...

Page 33: ...21BLD USERS MANUAL EM 7395 C Rev 7 Row A Pen setting item names Row B Pen setting parameters Lower range values Row C Upper range values Row A Display pen select item names Row B Display pen select parameters ...

Page 34: ...34 73VR21BLD USERS MANUAL EM 7395 C Rev 7 Row A Comment item names Row B Comment parameters ...

Page 35: ...ee Sign and click Select button 3 Click on C U 0043 Latin Capital Letter C or F U 0046 Latin Capital Letter F and click Select C and F can be entered directly on the keyboard after the Character Map is closed 4 Click Copy button to copy C or F 5 Open Pen setting individual window and paste the copied characters NOTE Max 4 characters can be used for an engineering unit C or F takes two characters C...

Page 36: ...rsion 3 or later is as follows Ver 3 00D When remote start after setting change the recorded data will be erased Dialog which confirms whether to accept it was added Ver 3 01 01 Anemoscope function added Ver 3 03 xx Supports Windows 10 Analog accumulation setting added ...