73VR21BLD USERS MANUAL EM-7395-C Rev.7
2. SETTING ON THE 73VR21BLD
2.1 FUNDAMENTAL SETTING
First, choose the number of input channels according to the hardware model number.
Model 73VR2102: 2 ch
Model 73VR2108: 8 ch
Model 73VR2104: 4 ch
Model 73VR2110: 10 ch
Model 73VR2106: 6 ch
Model 73VR2112: 12 ch
Figure 2.2. Fundamental setting.
2.2 SYSTEM SETTING
The System setting menu appears as below.
Figure 2.2. System setting.
CAUTION
Linger time setting is available only on the 73VR21x unit. Not selectable on the 73VR21BLD.
2.2.1 OPERATING MODE
Choose among the following options.
DEMO
Demonstration mode
You can run the 73VR21x program without actual signal
input for learning, evaluation and demonstration when you
choose DEMO.
Normal
Running mode
Choose this option when you connect actual input signals to
the 73VR21x.
2.2.2 TEMPERATURE UNIT
Choose among the following options.
Centigrade
Centigrade (Celsius)
Fahrenheit
Fahrenheit
2.2.3 START MODE
Choose among the following options.
Cold Start
At a restart, the 73VR21x stands by showing the initial view.
Hot Start
At a restart, the 73VR21x automatically starts recording.
2.2.4 DATA STORING FORM
Choose among the following options.
Float
Floating point
1 data size: 4 bytes
Short int
Short integer
Integer data multiplied by 10 (2-byte-long data)