9
73VR21BLD USERS MANUAL EM-7395-C Rev.7
2.3 DATA STORING METHOD
The Data storing method setting menu appears as below.
Figure 2.3. Data storing method.
2.3.1 STORING INTERVAL
The data is stored in time intervals preset as the Storing interval. Choose among the following options:
100msec
100 milliseconds
500msec
500 milliseconds
1sec
1 second
2sec
2 seconds
5sec
5 seconds
10sec
10 seconds
1min
1 minute
10min
10 minutes
Total recording time in a CF Card depends upon the storing interval selection. Selecting greater storing interval al-
lows longer recording time, though the data are more thinned, which may jeopardize the data accuracy.
CAUTION !
When the storing interval setting is changed, previously stored data are overwritten with new data.
2.3.2 STORING SETTING
There Five (5) storing modes as explained below:
No storing
No recording
Data is plotted on the chart or displayed on the digital meter
or bargraph, but no data is stored in the CF Card.
Normal
Normal storing mode
Recording is manually initiated and stopped. Data is con-
tinuously stored while the recording is on.
Remote trigger Remote trigger recording Data is automatically recorded while the external trigger
mode
condition (analog or discrete input) is true.
Event recording Event recording mode
The 73VR21x detects an external event by trigger signal,
and stores preset number of samples (max. 1200 respec-
tively) before and after the moment of event.
Time specified Store at defined time
Recording is automatically initiated and stopped at a
mode
predefined time.