53U
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
EM-6485-B Rev.21 P. 3 / 52
■
ENVIRONMENT
• Indoor use.
• Do not install the unit where it is directly exposed to rain,
water droplets or sunlight.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 90% RH in
order to ensure adequate life span and operation.
• Contrast of the LCD screen depends upon viewing angles.
Choose the height and angle where it is the most legible.
• Do not apply physical impact to the front face.
• To ensure the designated ingress protection, insert the
gasket as shown below before attaching the mounting
brackets.
Mounting Bracket
Panel
Gasket
■
WIRING
• Wiring to the unit must be conducted by qualified service
personnel.
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■
AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
PERFORMANCE
Accuracy (at 23°C ±10°C or 73.4°F ±18°F, 45 – 65 Hz)
Voltage
: ±0.3% (±0.2% for Option /H)*
Current
: ±0.3% (±0.2% for Option /H)*
Power
: ±0.5%*
Power factor
: ±0.5%
Frequency
: ±0.1%*
Energy
: ±1% (±0.5% for Option /H)
Harmonic contents
: ±1%*
Analog out put
: Accuracy of assigned measurand or
±0.2%, whichever is greater.
Response time
: ≤ 2 seconds (0 – 99%)
≤ 3 seconds for frequency and harmonic contents
* In percentage of the spans: 480V for voltage, 1A or 5A for
current, 4155W (5A) or 831W (1A) for active power. The de-
scribed accuracy levels are ensured at the input 1% or more
for phase 2 current with 3-phase/3-wire unbalanced load, for
neutral current with 3-phase/4-wire unbalanced load, and
neutral current with 1-phase/3-wire.
■
INPUT
Frequency
: 50 – 60 Hz
Voltage Input
Rated voltage
:
Line-to-line (delta voltage)
: 480V
Line-neutral (phase voltage)
: 277V
(for single phase/2-wire and single phase/3-wire)
Consumption VA
: ≤ U
LN2
/ 300 kΩ / phase
Current Input
Rated current
: 1A or 5A
Consumption VA
: ≤ I
2
· 0.01 Ω / phase
Contact Input
: 24V DC or 110V DC (input resistance 6 kΩ)
Auxiliary power supply
:
100 – 240V AC, 8VA max., 50 – 60 Hz
110 – 240V DC, 4W max. (UL approval is not available)
■
OUTPUT
Modbus
Interface
: Conforms to TIA/EIA-485-A
Protocol
: Modbus RTU
DC Current Ou tput
: 4 – 20mA DC, load resistance: 270 Ω
maximum
DC Voltage Out put
: 1 – 5V DC, load resistance: 5000 Ω
minimum
Open Collector
Programmable for either alarm or energy count.
Max. rated load
: 130V DC @50mA
Continuous rated load
: 130V DC @30mA
■
Measurement category
: CAT.III
■
Auxiliary power supply installation category
: CAT.II
The definition of the measurement category
CAT.I
:
Circuits not directly connected to the main pow-
er supply
CAT.II
:
Circuits directly connected to low-voltage facility
CAT.III
:
Circuits in building facility
CAT.IV
:
Power sources for low-voltage facility