47LPA

P.  / 5

EM-955-B Rev.2

 ADVANCED SETTING MODE

Shift

Shift

Alarm/

Scaling Factor

Measuring Mode

Brightness

Automatic Return Time 

to Measuring Mode

Transition Time to

Lockout Setting Mode

C1 / C2 / C3 / C4 / C5

00...99

00...99

00.0...99.9

Hold down Alarm/   + Scale/    button

at once for 

3 seconds

Hold down Alarm/    or Scale/    button

for 

1 second

Shift

Shift

Alarm/

Alarm/

Alarm/

Alarm/

Alarm/

Alarm/

Alarm/

Shift

Alarm/

Alarm/

Advanced Setting Mode

Version Indication

Display Refreshing Rate

001...999

Alarm/

A

A

Set value

Setting Parameters

Shift

Scale/

Alarm/

Low End Cutout

Low End Cutout Value

OFF / ON

000...999

Shift

Alarm/

Scale/

Alarm/

Alarm/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

Scale/

...

...

...
...

PARAMETER

Scaling factor
Low-end cutout

Low-end cutout value
Brightness

Automatic return time to Measuring Mode

Low-end cutout: Input signal below the preset cutout value is forcibly cut to 0.

 

Set for the three lowest digits of the scaled range (disregarding the decimal point)

 

With the cutout set to OFF, the low-end cutout value setting is locked.

Automatic return time to Measuring Mode: The display goes back automatically to Measuring Mode if the front buttons are left untouched

 

for the specified time period while it is in one of the setting modes (except the loop test output mode).

 

With this value set to 0, the display must always be exited manually from the setting mode.

Transition time to Lockout Setting Mode: The display goes to Lockout Setting Mode only when the designated buttons are pressed for the

 

specified time duration.

*

1.  F00.0 = 25 msec. refreshing rate

Specify in seconds

Brightness level 1 (dark)

Low-end cutout value setting

Low-end cutout ON

Low-end cutout OFF

Brightness level 4
Brightness level 5 (bright)

Brightness level 3

Brightness level 2

Frequency/counting scaled to 1/n

INDICATORS

FUNCTION

DEFAULT

VALUE

DISPLAY

Fnc
Fnc

Zro Fnc

D/P Fnc

D/P Fnc
D/P Fnc

Transition time to Lockout Setting Mode

Specify in seconds

Fnc

Version indication

Version number, indication only

N/A

N/A

N/A

...

Fnc

Display refreshing rate 

*

1

Specify in seconds

Summary of Contents for 47LPA

Page 1: ...erly indicate it POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 100 240V AC rating 85 264V 50 60 Hz appro...

Page 2: ...the H alarm is tripped HH turns on when the HH alarm is tripped P turns on when none of the other alarms is tripped 3 Function indicators Indicate the device status 4 Max Min button Used to switch th...

Page 3: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 20 M3 SCREW TERMINAL 2 M3 SCREW 10 M3 SCREW TERMINAL INSTALLATION HOW TO MOUNT THE UNIT ON A PANEL The watertight packing must be in place to hold the...

Page 4: ...lar devices to the input terminals to eliminate the input signals instability 8V 5k COM 3 4 5 1 2 Short EXC OC JP INP COM DI SENSOR EXCITATION INPUT CONTROL INPUT SHORT CIRCUIT EXC OC JP INP COM DI SE...

Page 5: ...ut Setting Mode Go through the lockout settings Measuring Mode Hold down Alarm or Scale button for 1 second Hold down Scale button for 3 seconds Measuring Measuring stopped 3 Mode transition 1 Preset...

Page 6: ...e button shifts one to the previous Changing parameters Pressing Shift button while one of the parameter settings is indicated on the display shifts the panel meter into the setting standby mode The d...

Page 7: ...0000 Hold down Scale button for 3 seconds Hold down Alarm or Scale button for 1 second Shift Shift Alarm Scale Alarm Alarm Scale Alarm Alarm Scale Alarm Scale Alarm Shift Shift Alarm Scale Alarm Scal...

Page 8: ...frequency for F10K F0 1M 120 kHz Note 2 Turn off the input signal while changing the input type 4 positions or none Decimal point position Display value for Input Scaling Value B Input value for Full...

Page 9: ...he desired output value Analog output 0 5 Analog output 100 Analog output function mode Proportional to the display value Fnc Zro Spn Fnc Proportional to the scaling value Analog output 0 adjustment A...

Page 10: ...d L ON Delay Time 19999 19999 0000 9999 00 99 Shift Shift Alarm Alarm Alarm Alarm Alarm Alarm L Coil at Alarm RYEN RYDN Shift Alarm Alarm Shift L Trip Action LMHI LMLO Alarm Alarm LL Coil at Alarm RYE...

Page 11: ...Alarm HH Coil at Alarm RYEN RYDN Shift Alarm Alarm Shift HH Setpoint 19999 19999 Shift H Setpoint H Deadband H ON Delay Time 19999 19999 0000 9999 00 99 Shift Shift Alarm Alarm Alarm Alarm Alarm Alarm...

Page 12: ...me H ON delay time seconds H Deadband hysteresis value H Setpoint value H Fnc H trip action H Hi trip H Fnc H Lo trip H coil at alarm H Coil energized at alarm H Fnc H Coil de energized at alarm D P H...

Page 13: ...e scaled range disregarding the decimal point With the cutout set to OFF the low end cutout value setting is locked Automatic return time to Measuring Mode The display goes back automatically to Measu...

Page 14: ...1 Preset time can be specified with Transition Time to Lockout Setting Mode in Advanced Setting Mode A Scale Scale Scale Scale Scale Set value Setting Parameters A Alarm Alarm PARAMETER Alarm setting...

Page 15: ...r reading Non volatile memory error writing 1 All parameter settings are reset to the factory default values If the unit does not recover its function after the initialization repairing in the factory...