background image

47LPA

P. 5 / 5

EM-955-B Rev.2

M-SYSTEM WARRANTY

M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such 
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive 
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this 
warranty.  To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original 
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR 
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

ERROR MESSAGES

MAIN DISPLAY

Input error, Out of the measuring range
Non-volatile memory error (reading)
Non-volatile memory error (writing)

*

1.  All parameter settings are reset to the factory default values.  If the unit does not recover its function after the initialization, repairing

 

in the factory may be required.

Increase/decrease the input signal until it is back within the measuring range.
While the error message is on the display, press Up button for 3 seconds or 

more to initialize the unit to its factory default status.

*

1

 

Repair is needed if the display does not recover after the power is reset.

ERROR MESSAGE

WHAT TO DO

Internal data error

CHARACTER SET

0 1 2

4

3

5 6 7

9

8

– A B

D

C

E F G

I

H

J K L

N

M

O P Q

S

R

T U V W X

Z

Y

 LOOP TEST OUTPUT MODE

Shift

Loop Test Output

Measuring Mode

-19999...19999

Set value

Setting Parameters

Hold down Alarm/    + Scale/    + Shift

button for 

5 seconds

Hold down Alarm/    or Scale/    button

for 

1 second

Loop Test Output Mode

*

1. Hold down Alarm/    or Scale/    button for 

1 second to return to the measuring mode while setting parameters.

*

1

PARAMETER

Loopt test output: Pressing [Shift] button switches the signal to increase (          ON) or decrease (          ON), and then pressing [Up] 

 

button controls it toward the desired output value.

 

Alarm trip functions according to the scaling values during the loop test.

 

*

1. The specified decimal point position is applied to the loop test output value.  -19999 to 19999 when ‘No decimal fraction’ is specified.

INDICATORS

/

FUNCTION

DEFAULT

VALUE

DISPLAY

Tch Fnc

Min

Max

...

Loop test output

Scaling value for the loop test output

(display blinking)

Zro Spn D/P

N/A

Max

Min

*

1

Summary of Contents for 47LPA

Page 1: ...erly indicate it POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 100 240V AC rating 85 264V 50 60 Hz appro...

Page 2: ...the H alarm is tripped HH turns on when the HH alarm is tripped P turns on when none of the other alarms is tripped 3 Function indicators Indicate the device status 4 Max Min button Used to switch th...

Page 3: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 20 M3 SCREW TERMINAL 2 M3 SCREW 10 M3 SCREW TERMINAL INSTALLATION HOW TO MOUNT THE UNIT ON A PANEL The watertight packing must be in place to hold the...

Page 4: ...lar devices to the input terminals to eliminate the input signals instability 8V 5k COM 3 4 5 1 2 Short EXC OC JP INP COM DI SENSOR EXCITATION INPUT CONTROL INPUT SHORT CIRCUIT EXC OC JP INP COM DI SE...

Page 5: ...ut Setting Mode Go through the lockout settings Measuring Mode Hold down Alarm or Scale button for 1 second Hold down Scale button for 3 seconds Measuring Measuring stopped 3 Mode transition 1 Preset...

Page 6: ...e button shifts one to the previous Changing parameters Pressing Shift button while one of the parameter settings is indicated on the display shifts the panel meter into the setting standby mode The d...

Page 7: ...0000 Hold down Scale button for 3 seconds Hold down Alarm or Scale button for 1 second Shift Shift Alarm Scale Alarm Alarm Scale Alarm Alarm Scale Alarm Scale Alarm Shift Shift Alarm Scale Alarm Scal...

Page 8: ...frequency for F10K F0 1M 120 kHz Note 2 Turn off the input signal while changing the input type 4 positions or none Decimal point position Display value for Input Scaling Value B Input value for Full...

Page 9: ...he desired output value Analog output 0 5 Analog output 100 Analog output function mode Proportional to the display value Fnc Zro Spn Fnc Proportional to the scaling value Analog output 0 adjustment A...

Page 10: ...d L ON Delay Time 19999 19999 0000 9999 00 99 Shift Shift Alarm Alarm Alarm Alarm Alarm Alarm L Coil at Alarm RYEN RYDN Shift Alarm Alarm Shift L Trip Action LMHI LMLO Alarm Alarm LL Coil at Alarm RYE...

Page 11: ...Alarm HH Coil at Alarm RYEN RYDN Shift Alarm Alarm Shift HH Setpoint 19999 19999 Shift H Setpoint H Deadband H ON Delay Time 19999 19999 0000 9999 00 99 Shift Shift Alarm Alarm Alarm Alarm Alarm Alarm...

Page 12: ...me H ON delay time seconds H Deadband hysteresis value H Setpoint value H Fnc H trip action H Hi trip H Fnc H Lo trip H coil at alarm H Coil energized at alarm H Fnc H Coil de energized at alarm D P H...

Page 13: ...e scaled range disregarding the decimal point With the cutout set to OFF the low end cutout value setting is locked Automatic return time to Measuring Mode The display goes back automatically to Measu...

Page 14: ...1 Preset time can be specified with Transition Time to Lockout Setting Mode in Advanced Setting Mode A Scale Scale Scale Scale Scale Set value Setting Parameters A Alarm Alarm PARAMETER Alarm setting...

Page 15: ...r reading Non volatile memory error writing 1 All parameter settings are reset to the factory default values If the unit does not recover its function after the initialization repairing in the factory...

Reviews: