51
Pressing and holding the
C
(Scan Model) or
c
(System Model) button
for 2.5 seconds toggles the user into and out of the dynamic regroup group set.
A double beep will sound for entry or exit. The display will indicate
REGR_0x
where "x" is a digit of 1 to 8 indicating the group when dynamic
regroups has been enabled by the user. If the radio is in dynamic regroup and
the user selects a group that has not been regrouped, the display will show
NO
ENTRY
. The radio will be prevented from transmitting and receiving calls in
this condition except for scanned groups.
Emergency Operation
If the pre-programmed group set on the currently selected system contains an
EMER/HOME group and the radio is in dynamic regroup, the radio will exit
dynamic regroup and declare the emergency on the HOME group. If no
EMER/HOME group is present, the radio will declare the emergency on the
currently selected dynamic regroup group.