75.5947.04 LZR-FLATSCAN SW 20200612
Page 11 of 16
75.5947.04 LZR-FLATSCAN SW 20200612
Page 11 of 16
2x
3x
1x
x
5x
1x
The access code is recommended for sensors installed close to each other.
After unlocking, the red LED
flashes and the sensor can be
adjusted by remote control.
If the red LED flashes quickly after unlocking, you need
to enter an access code from 1 to 4 digits.
If you do not know the access code,
cycle the power
.
During 1 minute, you can access the sensor without
introducing any access code.
= field width: 2.35 m
To end an adjustment
session, always lock the
sensor.
Enter the existing code
x = number of flashes = value of the parameter
full reset
partial reset
It is recommended to use a different access code for each sensor in order to avoid changing settings on
both sensors at the same time.
HOW TO USE THE REMOTE CONTROL
SAVING AN ACCESS CODE
DELETING AN ACCESS CODE
CHECKING A VALUE
RESTORING TO FACTORY VALUES
ADJUSTING ONE OR MORE PARAMETERS