Page 8 of 16
75.5947.04 LZR-FLATSCAN SW 20200612
Page 8 of 16
75.5947.04 LZR-FLATSCAN SW 20200612
B
A
B
A
«click»
«click»
!
5
6
Check the correct positioning of the
safety fields by walk-testing according
to ANSI 156.10 standards.
Apply the cover starting on the narrow
side. Do not hesitate to push.
To remove the cover, position a screwdriver
in the notch and pull upwards until the
cover loosens.
If necessary, adjust the tilt angle of the laser curtain by turning the tilt
angle adjustment screw (from 2° to 10°).
Service Mode
deactivates all detection fields
for 15 minutes and
can be useful during an installation, a mechanical learn of the door, or
maintenance work.
• To enter Service Mode, push and hold the button for at least 3
seconds. The LED will turn off.
• To exit Service Mode, push and hold again for at least 3 seconds.
Service Mode is deactivated automatically when a teach-in is launched.
SERVICE MODE
Watch our FLATSCAN SW tutorial online:
bea-flatscan.com/tutorial
TESTING AND ADJUSTING
FINAL STEPS
Always launch a teach-in and test the correct positioning of the detection fields after making adjustments to
the angle, sensor position, or environment.
Verify that the sensor correctly detects based upon the ANSI 156.10 walk test. Make appropriate adjustments to the
sensor and/or door control, if necessary, to ensure that the system is ANSI-compliant.