![Lynx MiniModule S VD 3062 Reference Manual Download Page 18](http://html1.mh-extra.com/html/lynx/minimodule-s-vd-3062/minimodule-s-vd-3062_reference-manual_1954017018.webp)
Reference Manual S VD 3062 Version1.4
Page 18
Dip Switch 2
When set to
ON
this configures output 1 as reclocked, if
set to
OFF
output 1 is non-reclocked
Dip Switch 3
When set to
ON
this configures output 2 as reclocked, if
set to
OFF
output 2 is non-reclocked
Dip Switch 4
This switch configures enables emergency switching.
ON
activates the emergency switch. If the selected
input is lost, the modules will switch automatically to the
next active input.
OFF
disables emergency switching.
Dip Switch 5-8
Used for address configuration for optional remote
control panel on parallel or RS485 interface:
ADR 0:
Direct Connect for Panel Version 1 and 2
ADR 1 .
.
ADR 6:
Address of S VD 3062 for connection to
Panel Version 3 or via RS 485
Factory Preset Condition
The S VD 3062 is delivered preset for the following
mode of operation:
Local control
enabled
Outputs 1
non-reclocked
Outputs 2
non-reclocked
Emergency switch
disabled
If this is the mode of operation required, then no
adjustments are necessary.