Lynx MiniModule S VD 3062 Reference Manual Download Page 12

Reference Manual S VD 3062 Version1.4

 

Page 12   

 

Power Connections 

If using the module in a stand-alone application use 

the separate R PS 1 E (for Europe), R PS 1 U (USA) power 

brick option or the desk power supply R PS 3001-3. 
 

DC Power Connector 

The MiniModule has a captive power lead fitted to the 

module, with a male 5 pin locking bayonet connector. 
This connection provides DC power and also data 

connectivity to the module. Connector wiring is shown 

below. 
   

3

4

5 1

2

GND

+ 5V

i2C-SDA (data)

i2C-SCL (clock)

Power Connection

Data Connection

Male Connector

(view looking into connector from front)

 

 

 

Caution 

Only use the optional LYNX R PS power modules. Ensure 

the 5-pin power connector is locked securely in place. 

Summary of Contents for MiniModule S VD 3062

Page 1: ...Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www lynx technik com Reference Manual S VD 3062 SDI 6 2 Input Switch MiniModules Version 1 4...

Page 2: ...tten permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except...

Page 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 5: ...Control Panels 11 Power Connections 12 DC Power Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Unit...

Page 6: ...Reference Manual S VD 3062 Version1 4 Page 6 Auto Store 26 Specifications S VD3062 27 Available Options 28 Parts List 29 Service 29 Contact Information 30...

Page 7: ...Mbit s 270Mbit s 360Mbit s and will transparently pass data from 10Mbits s to 620Mbits s in non reclocked mode A analog reference input allows clean switching for synchronous inputs Inputs can be swit...

Page 8: ...he S VD 3062 MiniModule Video I O is made through standard BNC video connectors Module configuration is set via a small dip switch located behind a small access hole in the bottom of the module A conn...

Page 9: ...Reference Manual S VD 3062 Version1 4 Page 9 Figure 2 Module Layout...

Page 10: ...f high quality video cable for digital video connections to reduce the risk of interference or errors due to excessive cable attenuation Some guidelines for max cable length are shown below 250m 820 f...

Page 11: ...t Select for OUT1or Input select f or Panel Version1 PIN A13 A8 Input Select forOUT2 PIN B7 Output 1 select for Panel Version 1 PIN B6 Output 2 select for Panel Version 1 PIN A7 Panel connect Low Pane...

Page 12: ...dule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the module Connector wiring is shown belo...

Page 13: ...3010 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with the...

Page 14: ...ack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is p...

Page 15: ...ction is solid and locked in place A strain relief is included within the module to prevent excessive strain on the connection Signal connections should be made with care please ensure connections are...

Page 16: ...62 has an integrated micro controller which enables the module to be configured and controlled locally via the integral dip switch or from remote when using the optional R FR 3010 Rack Frame and contr...

Page 17: ...a microcontroller and flash ram When this switch 1 is set to ON any configuration settings made on the module with the dip switches will automatically be written into flash ram and stored see Auto Sto...

Page 18: ...les will switch automatically to the next active input OFF disables emergency switching Dip Switch 5 8 Used for address configuration for optional remote control panel on parallel or RS485 interface A...

Page 19: ...th the module Tables below show pinout of Sub D 25 pin female connector as provided on the adapter Sub D 25 pin female PIN Function 1 6 Config Input select for OUT 1 or Input select for Panel Version...

Page 20: ...6 OUT1 OUT2 390R 390R 390R 390R 390R 390R 390R 390R 5V 5V 5V 5V 5V 5V 5V 5V PIN12 25 5V PIN13 GND PIN20 PIN21 GND connect to GND for Panel detect unconnect for Panel Version 1 PIN1 PIN2 PIN3 PIN4 PIN5...

Page 21: ...l Version 1 9 22 Not used 10 Not used 23 Not used 11 Not used 24 Not used 12 25 Power 5V 100mA max 13 Power GND Panel Version 2 25 pin Sub D Connector female this table shows relevant subset from tabl...

Page 22: ...Reference Manual S VD 3062 Version1 4 Page 22 Panel Version 3 R CP 3062 D Sub 25 polig male...

Page 23: ...config Output 1 select 8 config Output 2 select 14 19 config Select SVD3062 1 6 20 config not connect 21 config connect to GND 9 22 not used 10 not used 23 not used 11 not used 24 not used 12 25 Power...

Page 24: ...l Panel with a serial interface Controller RS485 SVD3062 Loop Address Dip Switch Input Output 25 pin Sub D Connector female this table shows relevant subset from table page 18 PIN function 14 21 not u...

Page 25: ...control is enabled If the LED 3 is ON Green local control is enabled if LED 3 is OFF local control is disabled Front Panel Alarm Indicator There is also a single alarm LED on the front side of the mo...

Page 26: ...n the following continuous sequence 3 short flashes Pause 3 short flashes This uses the alarm LED located on the front of the module as well as any module edge LEDs green that may be used in the modul...

Page 27: ...odes reclocked 6 2 for SMPTE 259M C signals non reclocked 6 2 for transparent digital signals up to 622Mbits Performance Cable Equalization Up to 200M using Belden 8281 270Mbit s Jitter 0 2 UI Control...

Page 28: ...for single MiniModules Set for 5 MiniModules R FR 3005 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or can be extended with the R FR 3010...

Page 29: ...03 270 Service If you are experiencing problems or have questions concerning your S VD 3062 MiniModule please contact your local distributor for assistance We offer a fixed cost service exchange progr...

Page 30: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik man...

Page 31: ...Reference Manual S VD 3062 Version1 4 Page 31 This Page is intentionally left blank...

Page 32: ...Reference Manual S VD 3062 Version1 4 Page 32 Notes...

Reviews: