background image

9

MAC - Primary Software Functions

Inspect, Unlock Door Only 
Choose this function when you need 

to access  

a compartment

 without disabling/resetting a  

user-created passcode.

Enter your inspection password in the  

Inspection Password

” field (default code  

is 12345678).
Click “

Run

” to open the compartment.

Close the door when finished inspecting the 

compartment (the compartment will  

re-lock, and the user-created passcode will  

still be active).

1.

2.
3.

1

2

Run

Door Unlock and Code Clearing 
Choose this function when you need  

to disable/reset a user-created passcode

 and  

make the compartment available for a new user.

Enter your reset password in the “

Reset Password

”  

field (default code is 12345678).
Click “

Run

” to open the compartment and reset  

the user-created passcode.
Close the door when finished inspecting the  

compartment (the compartment will latch shut, and the door can be re-opened by 

pressing the unlock button on the corresponding keypad).

1.

2.

3.

RUN

1

2

Inspection Password Setting

4.

3.

1.

2.

Choose this function if you wish 

to change the  

inspection password

 to another password of your  

choosing (it can be set to match or be different  

than the reset password).

Enter your current inspection password in the  

Current Inspection Password

” field (if one has  

never been set, the default password is 12345678).
Enter a new inspection password in the  

New Inspection Password

” field (up to 8 digits).

Re-enter the new inspection password in the “

Confirm Inspection Password

”  field.

Click “

Run

” (a “Successful” message will pop up if the code was successfully reset).

4

1

2

3

Summary of Contents for LLTSW5-G

Page 1: ...Design 3 Product Diagram 4 Quick Start Instructions 5 WINDOWS Administration Access Instructions 6 Software Download 6 Software Install for Windows OS Users 6 Software Operation for Windows OS Users...

Page 2: ...ures 1 AC Outlet 1 USB Port per Bay 46 3 lbs Devices Supported Phones Chromebooks Tablets and Laptops with up to 17 Screens 17 5 W x 19 D x 22 6 H 12 8 W x 17 8 D x 4 3 H 22 9 W x 22 7 D x 24 3 H 57 3...

Page 3: ...wer Cord Connection Daisy Chain Power Connection Fuse Anchor Point for Cable Lock Rear Ventilation Holes Side Compartment Doors Access Keypads Ventilation Holes Front 1 2 3 4 5 6 7 8 Front Side Rear 1...

Page 4: ...tatus Indicator Red Locked Solid Green Unlocked Blinking Green Able to enter code Keypad Indicator Lights when keys are pressed Door Status Indicator Red Closed Green Open USB Charging Indicator Red C...

Page 5: ...as needed Close the door When the door lock status indicator blinks green enter a 4 digit PIN of your choice 1 4 5 6 2 3 Enter your 4 digit PIN on the keypad next to the locked compartment you wish t...

Page 6: ...r Windows Open the downloaded zip file 2 3 Connect your computer with the micro USB port on the side of the keypad corresponding to the locker you wish to access Double click the KeyLockerUSBHostApp i...

Page 7: ...abling resetting a user created passcode Enter your inspect code in the Inspect Code field default code is 12345678 Click Run to open the compartment Close the door when finished inspecting the compar...

Page 8: ...cker you wish to access When the software starts you will see an administration window open Click on one of the four following functions from the menu Inspect Unlock Door Only Door Unlock and Code Cle...

Page 9: ...e is 12345678 Click Run to open the compartment and reset the user created passcode Close the door when finished inspecting the compartment the compartment will latch shut and the door can be re opene...

Page 10: ...message will pop up if the code was successfully reset 4 1 2 3 If You Forget a Reset or Inspection Password 1 2 3 4 5 6 7 Select Reset Password Setting In all caps type HOW DO into the Current Reset...

Page 11: ...are frayed or damaged Do not unplug the cord by pulling on the cable GENERAL SAFETY WARNINGS This product is designed for indoor use only This product is not designed to be operated by children Do no...