9
QUICK LIFT L520E
EN
Step 5 :
Turn the 2 ramps upside down and connect the hydraulic power pack electrically to a 220V single-phase socket.
Press the «» button on the remote control to go upwards without stopping (do not extend the cylinder rod to the maxi
-
mum - maximum height from the ground to the highest point 40cm), press the «» button to go back down to the ground
without stopping. Repeat 2 or 3 times to expel air from the hydraulic system and cylinders.
Flip over the ramps and your QUICK LIFT is ready for use.
Up
STOP
Down
SAFTEY AREA
To achieve optimum safety, it is recommended to define an area in which other objects or walls will
be at a certain distance (2m minimum). All descent, exit and parking manoeuvres must be carried out
with the best possible attention from the operator. Nobody must be stand in the safety area. In order
to guarantee the operator’s safety, the control box must be located at a distance that allows an escape
route in case of emergency.
INSTALLATION
Once the tool has been removed from its packaging, assembled and positioned on the ground, perform a no-load test
to check the QUICK LIFT’s general operation.
There are two positions for locking the height of the QUICK LIFT, which we will call height 1 and height 2 (max. height)
in the rest of the manual.
Height 1
Height 2
Locking bar in locked
position height 1
Height 1 Height 2
First of all, the QUICK LIFT must never be lifted unladen (without load) to the maxi-
mum stop (above height 2). The ramps could get stuck and never come down again.
They are designed to support a load during lifting. If this happens to you, please refer
to the paragraph «Abnormalities, Causes, Remedies».
Make sure you have the necessary protection:
pair of glasses, safety shoes and gloves.
1/ UNLADEN INSTALLATION:
Connect the power cord of the hydraulic unit to a 230 V single-phase supply.