background image

9

QUICK LIFT L520E

EN

Step 5 :

 Turn the 2 ramps upside down and connect the hydraulic power pack electrically to a 220V single-phase socket.

Press the «» button on the remote control to go upwards without stopping (do not extend the cylinder rod to the maxi

-

mum - maximum height from the ground to the highest point 40cm), press the «» button to go back down to the ground 

without stopping. Repeat 2 or 3 times to expel air from the hydraulic system and cylinders. 

Flip over the ramps and your QUICK LIFT is ready for use.

Up

STOP

Down

     

SAFTEY AREA

To achieve optimum safety, it is recommended to define an area in which other objects or walls will 

be at a certain distance (2m minimum). All descent, exit and parking manoeuvres must be carried out 

with the best possible attention from the operator. Nobody must be stand in the safety area. In order 

to guarantee the operator’s safety, the control box must be located at a distance that allows an escape 

route in case of emergency. 

 

INSTALLATION

Once the tool has been removed from its packaging, assembled and positioned on the ground, perform a no-load test 

to check the QUICK LIFT’s general operation.

There are two positions for locking the height of the QUICK LIFT, which we will call height 1 and height 2 (max. height) 

in the rest of the manual.

             

Height 1  

Height 2

Locking bar in locked

position height 1

                      Height 1               Height 2  

First of all, the QUICK LIFT must never be lifted unladen (without load) to the maxi-

mum stop (above height 2). The ramps could get stuck and never come down again. 

They are designed to support a load during lifting. If this happens to you, please refer 

to the paragraph «Abnormalities, Causes, Remedies».

 Make sure you have the necessary protection: 

pair of glasses, safety shoes and gloves.

1/ UNLADEN INSTALLATION:

Connect the power cord of the hydraulic unit to a 230 V single-phase supply.

Summary of Contents for 3154020062184

Page 1: ...73502 V6 19 05 2021 EN 1 24 QUICK LIFT L520E Translation of the original notice...

Page 2: ...g Safety in case of mechanical fall YES 2 positions Safety in case of hydraulic hose rupture YES Electrical installation 220 V 50Hz Power 0 75 kW Hydraulic tank capacity 4L Noise level 70dA Ascent and...

Page 3: ...al safety devices and the emergency stop button Controls automatically return to the initial position No damage to the cylinders the power supply cable and the wired remote control cable Tight fasteni...

Page 4: ...te of Conformity EC Machinery Directive 2006 42 EC ROHS2 directive 2011 65 EU and its amendment 2015 863 Report No EN1493 2010 EN50581 2012 Control body TF C 1212 18 155 04 5A NGBEC1802310202 Organism...

Page 5: ...ification of the product Insufficient maintenance INTENDED INTENDED USE The QUICK LIFT is designed for the repair of passenger vehicles It allows vehicles to be lifted safely The maximum load of the Q...

Page 6: ...is not recommended to work next to a heat source The QUICK LIFT was not designed for use in a spray booth It is forbidden to use spare parts other than original parts certified by the manufacturer Ma...

Page 7: ...c hoses i The ramps are very similar but they are not interchangeable The mechanical safety must always be on the outside and the ramps pointing in the same direction STOP UP DN Transport handles Cast...

Page 8: ...onnections Step 3 The tank of the hydraulic unit is empty It must be filled with hydraulic oil or automatic transmission fluid before starting operation Approved fluids are general purpose hydraulic o...

Page 9: ...ty area In order to guarantee the operator s safety the control box must be located at a distance that allows an escape route in case of emergency INSTALLATION Once the tool has been removed from its...

Page 10: ...ther and therefore in the passage of the locking bars on the blocks This is nor mal On load the ramps will be synchronized and the offset will be corrected Pressing DN down will lower the ramps until...

Page 11: ...ng a vehicle with QUICK LIFT you should be aware of this Case 1 Do not deploy both ramps at full height when unladen One way to become familiar with the use of your QUICK LIFT is to raise and lower th...

Page 12: ...trol When the vehicle leaves the ground do not stop the deployment of the ramps until the first locking position is reached Never leave a vehicle elevated unless both safety bars are in the locked pos...

Page 13: ...the locking bars so that the 2 cams rest on the ground Press DN down until the ramps return to the initial position Please make sure that the cams slide smoothly through each passage of the locking bl...

Page 14: ...ress DN on the remote control to make sure that there is no more pressure in the circuit and that both ramps are on the ground MAINTENANCE TABLE Maintenance intervals Task Remarks Monthly Check clean...

Page 15: ...system is under pressure Wear protective equipment goggles gloves and safety shoes when handling the Quick Lift If hydraulic fluid comes into contact with the eyes enters the bloodstream or is swal l...

Page 16: ...ce parts are broken bent or cracked START UP The QUICK LIFT must be disposed of in accordance with the current environmental and disposal guidelines of the country in which it is located WARRANTY COND...

Page 17: ...17 QUICK LIFT L520E EN OPTIONS SKIDS FOR SUV r f 065017 A A A A x2 OPTIONS EXTENSIONS r f 066328 A A A A A A x2...

Page 18: ...4M Hydraulic Tube 5 Supporting Palm for SUV 4pcs optional Quick Lift components List 1 Lifting Frame 2 pcs 2 Rubber Plate 4pcs 3 Power Unit AC 220V 50Hz DC12V battery holder optional 4 4M Hydraulic Tu...

Page 19: ...t Breaker 10A250V M N L L AC220 PE JAT Emergency Stop HYDRAULIC CIRCUIT M Filter Electric machinery Overflow valve Two position two way electromagnetic reversing valve Single spring valve Synchronizin...

Page 20: ...ng stops The emergency stop button is functional Condition of the load bearing construction mechanical struc ture Condition of the locking blocks height 1 and height 2 Condition of locking bars cams a...

Page 21: ...21 QUICK LIFT L520E EN MAINTENANCE LOG...

Page 22: ...22 QUICK LIFT L520E EN...

Page 23: ...website Equipment in conformity with Moroccan standards Equipment in compliance with British requirements IP54 Protects against dust intrusion and water spray from all directions This hardware is sub...

Page 24: ...24 IMPORTER GYS FRANCE 1 RUE DE LA CROIX DES LANDES CS 54159 53941 SAINT BERTHEVIN CEDEX FRANCE...

Reviews: