• Turn off the power to your Quick Lift before performing any maintenance..
• Only original spare parts can be used «Spare parts»
• The recommended maintenance intervals must be observed «Maintenance table»
• For maintenance work that is not covered or indicated in the operating instructions, contact your distributor and/or
the manufacturer.
i
Clean the QUICK LIFT at least once a week to remove all dust and dirt that could de-
grade the proper functioning of the product in the long term. Use auto cleaning cloths.
Do not use any water nor flammable or corrosive liquids.
Visually inspect your QUICK LIFT before each use. Do not use it if you detect damage
or severe wear and tear.
Carry out maintenance work only when the QUICK LIFT is lifted, locked and unloaded.
To disconnect the hydraulic quick couplings make sure that the QUICK LIFT is comple-
tely on the ground as shown in the diagram below. Otherwise there will be hydraulic
leakage when disconnecting.
min
i
If you feel significant resistance when trying to disconnect a hydraulic coupling, it
means that pressure is still present. Press "DN" on the remote control to make sure
that there is no more pressure in the circuit and that both ramps are on the ground.
MAINTENANCE TABLE
Maintenance
intervals
Task
Remarks
Monthly
Check, clean and lubricate all moving parts, especially
the pins and sliding surfaces of the locking bars.
Check the condition of the rubber spacers and clean
them.
Check the locking bars, the locking cams and the
condition of the pins.
Check the condition of the hydraulic hoses, the cable
of the wired remote control and the power supply
cable.
Check the hydraulic oil level
Refer to "Check and lubrication point".
Replace if necessary (Refer to the exploded view
"Spare parts")
Complete if necessary:
Synthetic oil (5l) 32 Cst at 40°C (ref. 062160)
Annual
"Regular safety check"
Complete oil replacement"
For the test protocol, refer to "Regular safety
check
Every 5 years of
service
Replace the complete set of hydraulic hoses.
"Refer to the exploded view.
«Spare parts»
Maintenance must be carried out at regular intervals.
Use the «Regular Security Check» form and the Maintenance Log to archive regular and annual checks.
Make a copy of the QUICK LIFT status report and attach it to the operating instructions.
Regular safety checks must be carried out by an authorised person. It is recommended to perform maintenance simul
-
taneously.