13 |
P a g e
BRACKET/CLIP SPACING
Mountings should be within 200mm of the ends of the head channel and not more than 1
metre apart.
For stacking side add an extra bracket for support.
FACE FIT
1.
Measure the track and mark on the face or architrave of the
window where to attach the brackets.
2.
Check the drop (length) of the Lumishade and mark the height on
the wall or architrave, allowing for clearance.
3.
Attach the brackets by using (20mm x 6# Panhead) screws
supplied.
Minimum 3 screws per bracket
BRICK OR RENDERED SURFACES
Warning: Ensure you drill no closer than 25mm from the edge of these
surfaces as you may chip or breakout the brick or render.
INSTALLING THE TRACK
Check to see what side the control is on before proceeding.
Hold track up to the brackets ensuring front edge lip of the track
engages into the lip of the bracket, twist up and backwards to snap
the track on to the bracket.
Note: Longer tracks will require you to snap each bracket in turn.
ATTACHING THE PANELS
Start with the track in closed position and ensure the hooks are in the open position.
Pick one fabric panel up individually and hang one side in the second hook.
Connect the next fabric panel to the former panel by clicking the clear plastic hangers
together, then repeat.
Summary of Contents for Lumishade
Page 1: ...Lumishade Product Manual ...