22
0698-501 B200 - 08/2020
en
Motor
MI 4
MA/ME II 3 MA/ME II 5 MA/ME II 7
ME II 8
MD1xL
MD2xL
Pump tube
B200
350
200
550
400
650
1000
B200 PURE
350
200
550
400
650
1000
B200 Ex PURE
350
200
550
400
650
1000
B200 PVDF
150
150
350
350
400
1000
Statements in mPas
Table 3, Max. viscosity
The viscosity values specified in the table are reduced when pumping liquids with a density of more
than 1 kg/dm³.
Motor
MI 4
MA/ME II 3 MA/ME II 5 MA/ME II 7
ME II 8
MD1xL
MD2xL
Pump tube
B200
1.1
1.2
1.3
1.4
1.4
2.8
B200 PURE
1.1
1.2
1.3
1.4
1.4
2.8
B200 Ex PURE
1.1
1.2
1.3
1.4
1.4
2.8
B200 PVDF
1.1
1.2
1.3
1.4
1.3
2.8
Data in kg/dm³ / Determined with 3 m hose 3/4" and opened nozzle 3/4".
Table 4, Max. density
The density values specified in the table are reduced when pumping liquids with a viscosity of more
than 1 mPas.