15
0698-501 B200 - 08/2020
en
6. Operation
3
All connections and fittings are properly tightened
3
Valve spool on the container (IBC) open.
!
WARNING
Danger of injury and intoxication when handling hazardous liquids!
►
Always wear protective equipment when working on the pump.
►
Observe the maximum operating pressure and operating temperature. At high operating pressure,
containers or hoses can burst or become loose.
►
Supervise the pump tube or monitor with a flow monitoring device.
►
Fill at an appropriate speed to prevent splashing out of liquids.
►
Allow nozzle or cable end to drain after filling. There may still be liquid which would otherwise flow out
uncontrolled.
NOTICE
Damage of property as a result of dry running!
►
Pump tube may never run dry.
6.1 Taking out of operation
!
WARNING
Danger of injury and intoxication when handling hazardous liquids!
►
Disconnect the pump motor from the mains power supply.
►
Always close the valve spool on the container (IBC) before working on the pump.
►
Always wear protective equipment when working on the pump.
►
Collect any residual liquid escaping from the pump and hose line safely and dispose of it in an environ-
mentally friendly fashion.
►
Loosen clip, if necessary or remove mounting bracket.
►
Release wing nut on the container.
►
Pull off pump.
!
CAUTION
After removing the pump from the container, fingers can be injured by rotating parts!
►
Disconnect the pump motor from the mains power supply.
►
Do not reach into the intake port of the pump.