14
0698-501 B200 - 08/2020
en
5.2 Fasten the pump tube to the container (IBC)
3
A shut-off device is available on the container.
3
A check valve is mounted on the pump outlet to prevent inadvertent emptying of the container.
3
When using nozzles, the container (IBC) must not be higher than the maximum operating pressure
allows.
►
Screw the pump with wing nut at the outlet of the container. The pump outlet of the pump tube must
be levelled downwards. The pump is connected with the container via an adapter. Pump types made
of stainless steel can also be connected via the clamp socket with a hose line or pipe line (
→
Fig. 3,
Item 1).
►
Pump must be hung up with a clip
→
Fig. 3, item 2) in order to avoid overload at the container
outlet. For stainless steel pumps, the clip is fixed on the lifting eye and for pumps made of PVDF on
the hand wheel. Pump types made of stainless steel can also be firmly installed in a pipeline which is
designed for the total weight of the pump (approx. 6 kg).
5.3 Safe use
Only put the pump into operation if:
3
Motor fastened properly on pump tube
3
Motor and pump tube not damaged
3
Pump screwed tightly to container
3
For pumps made of stainless steel, the fixing screws on the pump tube are tightened firmly (
→
Fig. 1A)
3
Suitable and tested pressure lines and connections are used
3
Hose lines tightly and firmly connected to the pump
NOTICE
Damage of property as a result of dry running!
►
Open the valve spool on the container (IBC).
►
Container (IBC) must not contain any deposits.
►
Do not subject the outrun piece to tension or pressure (
→
Fig. 4).
►
Limit the bending moment M
B
at the outrun piece to 30 Nm. Also observe the information for the
container outlet.