background image

EcoSystem

®

 Energi Savr Node

TM

 Installation Guide

Lutron

®

  

|

  1

EcoSystem

®

 Energi Savr Node

TM

 

|

 Installation Guide

Control Panel Ratings

Control Power: 120-277 V   50/60 Hz  0.5 A
Output:  

18 V

  250 mA per 

EcoSystem

 link

Operating environment: 32 ˚F to 104 ˚F (0 ˚C to 40 ˚C)
Maximum humidity: 90% non-condensing
Thermal dissipation: 40 BTU/hr
Input Groups: 20 V

  65 mA per group

QS link: 24 V

  1 A  30 PDU (Power Draw Units)

Model number overview

QSN-1ECO-S 

EcoSystem Energi Savr Node

QSN-2ECO-S 

EcoSystem Energi Savr Node

QSN: 

Energi Savr Node

1: 

EcoSystem

 Digital Link             

2: 

EcoSystem

 Digital Links

ECO: 

EcoSystem

S: 

Surface mount

Please read this guide before installing.

Contents 

Page

Ratings and Model number overview ....................................1
Product overview..................................................................2
Wiring overview....................................................................2
Mounting ..............................................................................3
Control power wiring ............................................................3
EcoSystem Link wiring .........................................................4
Input group wiring ................................................................5
Contact closure inputs ..........................................................6
QS link wiring .......................................................................7
Applications .........................................................................9
Out of box functionality .........................................................9
System Programming Connection .......................................10
Troubleshooting ..................................................................11
Warranty ............................................................................12
Contact information ............................................................12

System Example

QS link

Control Power

120-277 V

Emergency 

Contact 

Closure 

Input

Contact 
Closure 
Input

Wireless  

Communication

Wired Daylight  
Sensors (up to 4)

2

Wired  
Daylight  
Sensors  
(up to 4)

1,2

EcoSystem

 

Digital Links 
(up to 64 ballasts each)

Wired Occupancy  
Sensors (up to 4)

Wired  
Occupancy  
Sensors 
(up to 4)

1

Wired 

EcoSystem

  

Wallstation or  
IR receivers 
(up to 4)

Wired  
Wallstation 
or IR Receivers 
(up to 4)

1

QSM (new!)

seeTouch

®

 QS Wallstation

IR Transmitter

IR Transmitter

   

Notes:

 

1  Up to 4 wired inputs total (of any type).
2  Up to 16 wired daylight sensors total 

per 

EcoSystem 

link.

Radio Powr Savr

TM

 

Occupancy  

Sensor (up to 10 

per QSM)

Radio Powr Savr

  

Daylight Sensor 

(up to 10 per QSM)

Pico

®

 Wireless 

Controller  

(up to 10 per 

QSM)

Summary of Contents for EcoSystem Energi Savr Node

Page 1: ...power wiring 3 EcoSystem Link wiring 4 Input group wiring 5 Contact closure inputs 6 QS link wiring 7 Applications 9 Out of box functionality 9 System Programming Connection 10 Troubleshooting 11 Warr...

Page 2: ...es The EcoSystem Energi Savr Node unit counts as 1 QS device and 1 100 zones on the QS link depending on system programming In a system a maximum of 100 wired or wireless daylight sensors 100 wired or...

Page 3: ...the following instructions to wire line voltage to the EcoSys tem Energi Savr Node unit WARNING Danger of Shock May result in serious injury or death DO NOT WIRE WHEN LIVE Switch off power to all pow...

Page 4: ...must be accessed by a certified electrician following local codes 1 Turn power off 2 Remove metal outer panel cover 3 Remove internal plastic line voltage shield 4 Wire the EcoSystem link from the Eco...

Page 5: ...it are used for troubleshooting If wiring is exposed when accessing buttons and LEDs the unit must be accessed by a certified electrician following local codes Note The EcoSystem Energi Savr Node unit...

Page 6: ...ergency level 100 by default and disable control from inputs and QS devices When the closure is restored ballasts and or drivers will return to their previous level Note The EcoSystem Energi Savr Node...

Page 7: ...ode unit counts as 1 QS device and 1 100 zones See diagram on the right for QS link wiring 1 Connect terminals 1 3 and 4 to all EcoSystem Energi Savr Node units 2 Each EcoSystem Energi Savr Node unit...

Page 8: ...coSystem Energi Savr Node unit Sivoia QS Shade Sivoia QS Smart Power Panel seeTouch QS Wallstations QS Control Link Sivoia QS Smart Power Panel Sivoia QS Shade seeTouch QS Wallstations EcoSystem Energ...

Page 9: ...one light levels will decrease when light sensed by daylight sensor increases IR Receivers IR Corresponding zones respond to On Off Scene Raise and Lower commands from compatible IR transmitters see I...

Page 10: ...ts connected to an EcoSystem Energi Savr Node unit via the QS Link except when part of a Quantum system Energi Savr Node app is required to program EcoSystem Energi Savr Node units except when part of...

Page 11: ...ash per 7 seconds More than one supply powering link QS QS Link Green 1 flash per second Green 1 flash per 7 seconds Link disconnected communication lost Green 5 flashes per second Incorrect data Off...

Page 12: ...LURE TO MEET ANY DUTY INCLUDING OF GOOD FAITH OR OF REASONABLE CARE NEGLIGENCE OR ANY OTHER PECUNIARY OR OTHER LOSS WHATSOEVER NOR FOR ANY REPAIR WORK UNDERTAKEN WITHOUT LUTRON S WRITTEN CONSENT ARISI...