3-2
Programming:
With the parameter 59-TRIP, the I
∗
t-trigger current is set. That means
currents < I
N
(device nominal current) can be set. Motors with outputs
smaller than the device nominal output are thus sufficiently protected from
overloading .
Factory setting: 59-TRIP = I
N
(Device nominal current)
3.3
Error messages
H1
Errors
Condition/cause
Remedy/comment
flashes
once
E-CPU
Error in computer
Switch off at mains and
switch on again (Reset)
twice
E-OFF
Mains switched off
flashes until UZK <150 V VF12xxL
or low voltage
< 300 V VF14xxL
3 times E-OC
Excess current cut-off
Check drive/ motor cable/
short circuit
U/f characteristics
4 times E-OV
Excess voltage,
Check mains/drive/
Motor generator
braking chopper
5 times E-OLM
Motor overloaded,
Check drive /motor/ventilation
I
∗
t switching off
6 times E-OLI
Inverter overloaded,
Check drive/ventilation
I
∗
t switching off
7 times E-OTM
Motor temperature
Motor overloaded, check instal-
lation conditions too high*
8 times E-OTI
Inverter temperature
Inverter overloaded, check
toohigh installation
conditions
9 times E-EEP
Error in EE-PROM
Switch off at mains and switch
on again (Reset)
*only possible with the PTC or PT1 designs
Acknowledge error by pressing stop/return key for at least 3 sec. or with
digital signal as described under 75-OPT1 (Chapter 6).