![Lust SMARTDRIVE VF1000 M Series Operation Manual Download Page 43](http://html1.mh-extra.com/html/lust/smartdrive-vf1000-m-series/smartdrive-vf1000-m-series_operation-manual_1950416043.webp)
3-1
3.2
Warning messages
(no fault reaction from the device)
Inverter malfunction
ATT1
Parameter alteration in online- mode (when motor running)
not allowed.
ATT2
Motor control via K
EY
P
AD
in online- mode not permitted.
ATT3
Access to Lust S
MART
C
ARD
in online- mode not permitted.
ATT4
System is in fault condition. Control via K
EY
P
AD
not permitted.
ATT5
Motor data must be complete for the selected function
e.g. I
∗
R Compensation.
ERROR
Invalid password
Acknowledge error by pressing start/enter-key.
Error with S
MART
C
ARD
-mode
ERR91
S
MART
C
ARD
is write-protected
ERR92
Error with plausiblity check.
ERR93
S
MART
C
ARD
not readable, inverter/servo-controller type incorrect.
ERR94
S
MART
C
ARD
not readable, parameter incompatible.
ERR96
Connection to S
MART
C
ARD
interrupted.
ERR97
S
MART
C
ARD
- data invalid (CS-Test).
ERR98
Insufficient memory on S
MART
C
ARD
(only MC6000).
Acknowledge error by pressing stop/return-key.
3
Operating and error diagnosis
3.1
Display
Position of LEDs:
41
42
43
44
45
46
n.c.
23
29
36
21
22
23
24
25
26
33
34
35
26
47
48
49
50
51
52
+
+
H2
H1
H1
yellow
H2
green
Meaning
Power off, no function
Power is switched on, after approxi-
mately 0.5 s Selftest, inverter ready
Inverter is started
Overload protection active
Error shut-down, flash rhythm H1
see chap. 3.2.2. Error message
Summary of Contents for SMARTDRIVE VF1000 M Series
Page 10: ...A 8 A 4 Manufacturer s declaration for frequency inverter ...
Page 11: ...A 9 ...
Page 13: ...A 11 ...