Insert the wall installation hous-
ing into the wall section. Ensure
the electrical flap close
-
off is
fitted exactly into the wall break
-
through pipe. Align the surround-
ing collar of the wall installation
housing
plaster
-
flush
as repre-
sented.
Fix the wall installation housing
in the wall section (e.g. with
construction foam).
Insert the electrical flap close
-
off
or the passive transition piece
into the wall installation housing
from internally and fix it with the
enclosed bolts.
Strip the insulation from the
cable to the electrical flap close
-
off 5
-
7mm und connect the elec-
trical flap close
-
off.
A separate assembly instruc-
tion is enclosed with the elec-
trical flap close
-
off.
Between the circumferential ribs
of the electrical flap close
-
off
respektively the passive transi-
tion piece a adhesive and filling
sealing must be applied circum-
ferentially (e.g. assembly adhesi-
ve 038733)
To prevent the connection of
ingressing condensate it must
be performed waterproof.