37
Compose the surface
-
mounting
set from its four wall parts by
simple interconnecting.
Insert the wall installation hous-
ing into the surface
-
mounting
set.
Insert the electrical flap close
-
off
and the passive transition piece
into the wall installation housing
from internally, and fix it with the
enclosed bolts.
red black white yellow
Cable to the elec-
trical flap close
-
off
Strip the insulation from the
cable to the electrical flap close
-
off 5
-
7mm und connect the elec-
trical flap close
-
off.
A separate assembly instruc-
tion is enclosed with the elec-
trical flap close
-
off.
Between the circumferential ribs
of the electrical flap close
-
off
respektively the passive transi-
tion piece a adhesive and filling
sealing must be applied circum-
ferentially (e.g. assembly adhesi-
ve 038733)
To prevent the connection of
ingressing condensate it must
be performed waterproof.
EN
seal circumferential
ribs